Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: RUFF NEON & LIGHTING MAINTENANCE INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RUFF NEON & LIGHTING MAINTENANCE INC. in 905 LORAIN BLVD., ELYRIA, OH 44035 (NAICS 238160). OSHA activity number 344801071.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ruff Neon & Lighting Maintenance INC. for free Get an email when a new federal OSHA severe-injury report for Ruff Neon & Lighting Maintenance INC. is published. One employer, no account, unsubscribe in one click.
Site address
905 LORAIN BLVD.
City
ELYRIA
State
OH
ZIP
44035
Mailing
295 WEST PROSPECT ST., PAINESVILLE, OH 44077
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 3, 2020
Abate by
Nov 30, 2020
Penalty
Initial $5,398 · Current $5,398
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.  a) Ruff Neon & Lighting Maintenance Inc., on or about June 19th, 2020, at the location of 905 Lorain Blvd., Elyria, OH, 44035: Employees were installing metal roof panels while exposed to fall hazards of approximately 16 to 20 feet without the benefit of fall protection.
Recent events (2)
  • · I (S) $5398
  • · Z (S) $5398

1926.503 C

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 3, 2020
Abate by
Nov 30, 2020
Penalty
Initial $5,398 · Current $0 Reduced
29 CFR 1926.503(c): The employer did not retrain affected employees  who already had been trained but demonstrated inadequate  understanding and skill required by paragraph (a) of this section:    a) Ruff Neon & Lighting Maintenance Inc., on or about June 19th, 2020, at the location of 905 Lorain Blvd., Elyria, OH, 44035: Employees were installing metal roof panels while exposed to fall hazards of approximately 16 to 20 feet were not retrained when changes in types of fall protection systems or equipment to be used rendered the previous training obsolete.
Recent events (2)
  • · I (S) $0
  • · Z (S) $5398

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344801071.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.