Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACCORD STEEL AND PRECAST ERECTORS, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ACCORD STEEL AND PRECAST ERECTORS, INC. in 67-91 GUEST STREET, BRIGHTON, MA 02135 (NAICS 238120). OSHA activity number 344806856.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Accord Steel and Precast Erectors, INC. — free Get an email when a new federal OSHA severe-injury report for Accord Steel and Precast Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
67-91 GUEST STREET
City
BRIGHTON
State
MA
ZIP
02135
Mailing
42 WINTER STREET UNIT #35, PEMBROKE, MA 02359
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
30
Ownership type
A

2 citations on file for this inspection.

1926.757 E02

Serious Gravity 5 3 instances 10 exposed
Issued
Nov 9, 2020
Penalty
Initial $4,554 · Current $4,554
29 CFR 1926.757(e)(2): Construction loads were placed on steel joists before all bridging was installed and anchored and all joist bearing ends were attached.   The employer did not ensure that bridging was installed on steel joists onto which construction loads, including bundles of steel decking, had been placed.  Instance A: On June 3 and June 9, 2020, decking bundles were supported by unbridged steel joists at the northwest side of the building.  Instance B: On June 3, 2020, decking bundles were supported by unbridged steel joists at the southeast side of the building.  Instance C:  On June 3, 2020, decking bundles were supported by unbridged steel joists at the west side of the building.
Recent events (3)
  • — W (S) $4554
  • — C (S) $4554
  • — Z (S) $4554

1926.757 E05

Serious Gravity 5 2 instances 4 exposed
Issued
Nov 9, 2020
Penalty
Initial $4,554 · Current $4,554
29 CFR 1926.757(e)(5): When construction loads were placed on steel joists, the employer did not ensure that the load was within 1 foot of the bearing surface of the joist end.     Location:  West and northwest sides of roof.  The employer did not ensure that decking bundles were placed more than one foot from the joist ends.