MILFORD, OH —
OSHA Inspection: LUIS GUTIERREZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LUIS GUTIERREZ in 1170 OH-131, MILFORD, OH 45150 (NAICS 238160). OSHA activity number 344807714.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LUIS GUTIERREZ
- Site address
- 1170 OH-131
- City
- MILFORD
- State
- OH
- ZIP
- 45150
- Mailing
- 2568 CARNEGIE STREET, DAYTON, OH 45406
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.20 B02
- Issued
- Sep 15, 2020
- Abate by
- Oct 2, 2020
- Penalty
- Initial $4,048 · Current $1,040 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers. a.) On or about June 25, 2020, the employer failed to perform frequent and regular inspections of the job sites, materials, and equipment thus exposing employees to a 12 foot 1 inch fall hazard located on a church roof.
Recent events (2)
- — I (S) $1040
- — Z (S) $4048
1926.501 B11
- Issued
- Sep 15, 2020
- Abate by
- Oct 2, 2020
- Penalty
- Initial $4,048 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): "Steep roofs." Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems. a.) On or about June 25, 2020, employees were exposed to a 12 foot 1 inch fall hazard while performing roofing work on a 6/12 steep pitched church roof and not using any means of conventional fall protection.
Recent events (2)
- — I (S) $0
- — Z (S) $4048
1926.502 A02
- Issued
- Sep 15, 2020
- Abate by
- Oct 2, 2020
- Penalty
- Initial $4,048 · Current $0 Reduced
General-duty citation text
29 CFR 1926.502(a)(2): Employers shall provide and install all fall protection systems required by this subpart for an employee, and shall comply with all other pertinent requirements of this subpart before that employee begins the work that necessitates the fall protection. a.) On or about June 25, 2020, the employer failed to install all fall protection systems before employees began working on a 12 foot 1 inch high church roof top.
Recent events (2)
- — I (S) $0
- — Z (S) $4048
1926.503 A01
- Issued
- Sep 15, 2020
- Abate by
- Oct 2, 2020
- Penalty
- Initial $4,048 · Current $0 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. a.) On or about June 25, 2020, employees were not trained to recognize fall hazards such as, but not limited to, a 12 foot 1 inch fall hazard while performing roofing work on a 6/12 pitched church roof, nor were they trained on when to utilize a fall protection system.
Recent events (2)
- — I (S) $0
- — Z (S) $4048
1926.1053 B01
- Issued
- Sep 15, 2020
- Abate by
- Oct 2, 2020
- Penalty
- Initial $3,470 · Current $3,470
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a.) On or about June 25, 2020, employees were exposed to a 9 foot 3 inch fall hazard while using an extension ladder to climb down from the unprotected edge of the roof surface without extending the side rails of the ladder at least 36 inches above the landing surface.
Recent events (2)
- — I (S) $3470
- — Z (S) $3470
More inspections at Luis Gutierrez
View Luis Gutierrez's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344807714.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.