Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: AJF CONSTRUCTION COMPANY, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of AJF CONSTRUCTION COMPANY, LLC in 222 TULIP STREET, LIVERPOOL, NY 13089 (NAICS 238990). OSHA activity number 344812847.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AJF Construction Company, LLC — free Get an email when a new federal OSHA severe-injury report for AJF Construction Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
222 TULIP STREET
City
LIVERPOOL
State
NY
ZIP
13089
Mailing
102 NEWBERRY HOLLOW LANE, SYRACUSE, NY 13210
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
15
Ownership type
A

5 citations on file for this inspection.

1926.56 A

Serious Gravity 1 3 instances 7 exposed
Issued
Oct 28, 2020
Abate by
Nov 9, 2020
Penalty
Initial $2,313 · Current $1,268 Reduced
29 CFR 1926.56(a): While work was in progress, construction areas, ramps, runways, corridors, offices, shops or storage areas were not lighted to the minimum illumination intensities as listed in Table D-3 of 29 CFR 1926.56:  a)  At the jobsite, inside building #1, on or about 6/30/20:  Workers were transiting through the stairwell and hallways where no lighting was provided and readings were measured between .01 and .06 lumens and was occasionally too dark to read the device.    b)  At the jobsite, inside building #2, on the first floor, on or about 6/30/20:  Workers were transiting through and working inside areas where no lighting was provided and readings were measured between .01 and .06 lumens and was occasionally too dark to read the device.   c)  At the jobsite, inside building #3, on the first floor and second floor,on or about 6/30/20:  Workers were transiting through a hallway where no lighting was provided and readings were measured between .01 and .05 lumens.
Recent events (2)
  • — I (S) $1267.8
  • — Z (S) $2313

1926.403 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 28, 2020
Abate by
Nov 9, 2020
Penalty
Initial $3,084 · Current $1,850 Reduced
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose.  a)  At the jobsite, inside building #2, on or about 6/30/20:  Workers were using power tools powered through a metal quad box that was not secured to a solid surface, the item is not designed for this purpose.
Recent events (2)
  • — I (S) $1850.2
  • — Z (S) $3084

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 28, 2020
Abate by
Nov 3, 2020
Penalty
Initial $5,398 · Current $3,239 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a)  At the jobsite, on the second floor of building #2, on or about 6/30/20:  Employees worked in close proximity to an unguarded stairwell opening, and were not provided other fall protection, exposing workers to falls of 10 feet to the lower level.
Recent events (2)
  • — I (S) $3238.8
  • — Z (S) $5398

1926.1052 A03

Serious Gravity 10 1 instance 7 exposed
Issued
Oct 28, 2020
Abate by
Nov 9, 2020
Penalty
Initial $5,398 · Current $3,239 Reduced
29 CFR 1926.1052(a)(3): Riser height and/or tread depth was not uniform within each flight of stairs:   a)  At the jobsite, inside building #2, on or about 6/30/20:  Workers were using a temporary stairwell to access and egress the second floor of the building where the treads of that stairwell were inconsistent in both rise and run on each step.
Recent events (2)
  • — I (S) $3238.8
  • — Z (S) $5398

1926.1052 C01 I

Serious Gravity 5 3 instances 7 exposed
Issued
Oct 28, 2020
Abate by
Nov 9, 2020
Penalty
Initial $4,626 · Current $2,776 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  a)  At the jobsite, inside building #1, on or about 6/30/20:  Workers were using a finished stairwell to access and egress the second floor of the building where no handrail was provided.  b)  At the jobsite, inside building #2, on or about 6/30/20:  Workers were using a temporary stairwell to access and egress the second floor of the building where no handrail was provided.  c)  At the jobsite, inside building #3, on or about 6/30/20:  Workers were using a finished stairwell to access and egress the second floor of the building where no handrail was provided.
Recent events (2)
  • — I (S) $2775.8
  • — Z (S) $4626

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344812847.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.