FARMINGTON, CT —
OSHA Inspection: TRUMPF INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRUMPF INC. in 111 HYDE ROAD, FARMINGTON, CT 06032 (NAICS 333517). OSHA activity number 344822515.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRUMPF INC.
- Site address
- 111 HYDE ROAD
- City
- FARMINGTON
- State
- CT
- ZIP
- 06032
- Mailing
- 111 HYDE ROAD, FARMINGTON, CT 06032
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333517
- Employees
- 540
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.28 B06 I
- Issued
- Oct 23, 2020
- Penalty
- Initial $5,571 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.28(b)(6)(i): (i) Each employee less than 4 feet (1.2 m) above dangerous equipment is protected from falling into or onto the dangerous equipment by a guardrail system or a travel restraint system, unless the equipment is covered or guarded to eliminate the hazard. On or about July 13, 2020 a compactor located in the dock area of Building 1 was observed to have a guardrail measuring only 33 inches above the dock surface. This exposed employees to falls into the compactor, which could result in injury.
Recent events (2)
- — I (S) $5000
- — Z (S) $5571
1910.29 B02 III
- Issued
- Oct 23, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.29(b)(2)(iii): (iii) Intermediate vertical members (such as balusters) are installed no more than 19 inches (48 cm) apart: On or about July 13, 2020 the space between a compactor and the existing guardrail was found to be 25 inches wide and was 52 inches in height from the dock platform to the ground. This exposed employees to falls due to the lack of a guardrail in this space.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.335 A01 II
- Issued
- Oct 23, 2020
- Abate by
- Dec 11, 2020
- Penalty
- Initial $8,193 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(ii): Protective equipment was not maintained in a safe, reliable condition and/or was not periodically inspected or tested: On or about July 13, 2020 an employee was found to be in possession of electrical rubber protective gloves that were beyond the six month inspection date. This exposed the employee to electrocution, shock and or burn injuries as a result.
Recent events (2)
- — I (S) $5000
- — Z (S) $8193
1910.335 A01 I
- Issued
- Oct 23, 2020
- Abate by
- Dec 11, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: On or about July 13, 2020 an employee was missing his balaclava hood that is part of the arc flash PPE. The absence of an arc flash balaclava hood exposed the employee to burns.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 I
- Issued
- Oct 23, 2020
- Abate by
- Dec 11, 2020
- Penalty
- Initial $8,193 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about July 17, 2020 specific procedures for lockout/tagout did not exist for two CNC grinders. This exposed employees to possible electrocution, shock, and burns.
Recent events (2)
- — I (S) $5000
- — Z (S) $8193
1910.147 C06 I
- Issued
- Oct 23, 2020
- Abate by
- Dec 31, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: 111 Hyde Road, Farmington, CT: On or about July 7, 2020, the employer had not reviewed the lockout/tagout program annually. The last review date was July 31, 2017.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Oct 23, 2020
- Abate by
- Dec 11, 2020
- Penalty
- Initial $8,193 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about July 7, 2020 a belt sander in the maintenance shop area of Building 2 was found to be missing guarding at the bottom ingoing nip point. This exposed employees to hand, arm, and eye injuries associated with the sanding process. b) On or about July 13, 2020 a Heidenreich and Harbeck Lathe in Building 1 was found to be missing a guard over the lead screw. This exposed employees to hand and arm injuries associated with the operation of this machine. c) On or about July 13, 2020 a horizontal band saw located in the Tooling Department of Building 1 was not provided with a guard for the unused portion of the blade. This exposed employees to hand injuries from operating. d) On or about July 13, 2020 a Okuma LB15 Lathe was found to have an interlock that allowed the doors to open approximately 4 1/2 inches. This opening was too wide and exposed employees to hand and arm injuries if they reached in during operation.
Recent events (2)
- — I (S) $5000
- — Z (S) $8193
1910.213 C01
- Issued
- Oct 23, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: Building 2 maintenance area: On or about July 7, 2020 a Dayton table saw was found to be missing guarding of the blade. This exposed employees to hand, arm, and eye injuries associated with using a table saw.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Oct 23, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about July 7, 2020 an air nozzle in the maintenance shop area of Building 2 used for cleaning purposes was found to be at 100 p.s.i.. This exposed employees to eye and face injuries from debris. b) On or about July 13, 2020 an air nozzle in Building 1 near the Maching G400 machine was found to be at 35 p.s.i.. This exposed employees to eye and face injuries from debris. c) On or about July 13, 2020 an air nozzle in Building 1 near the Fastums System (1E03 area) was found to be at 50 p.s.i.. This exposed employees to eye and face injuries from debris.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 I B
- Issued
- Oct 23, 2020
- Abate by
- Dec 11, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i)(B): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of the working space in front of electrical equipment was less than the width of the equipment or 762 mm (30 inches), whichever was greater : On or about July 13, 2020 an electric panel box in Building 1 was found to be obstructed by piping. The width was found to be 18 1/2 inches and the depth was found to be 8 1/2 inches. Employees were exposed to possible prolonged exposure to electrical sources due to the electric panel box being inaccessible.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Trumpf INC.
View Trumpf INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333517)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344822515.