Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: WEST END FIREWOOD, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WEST END FIREWOOD, INC. in 496 PURGATORY RD, WHITINSVILLE, MA 01588 (NAICS 454319). OSHA activity number 344824289.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch West END Firewood, INC. for free Get an email when a new federal OSHA severe-injury report for West END Firewood, INC. is published. One employer, no account, unsubscribe in one click.
Site address
496 PURGATORY RD
City
WHITINSVILLE
State
MA
ZIP
01588
Mailing
496 PURGATORY RD, WHITINSVILLE, MA 01588
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
454319
Employees
15
Ownership type
Private (A)

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 11, 2020
Abate by
Oct 29, 2020
Penalty
Initial $5,398 · Current $3,398 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    496 Purgatory Rd, Whitinsville, MA: On July 8, 2020 and at times prior, employees did not utilize the energy control procedure when they reached into the splitting/sawing area to unjam a firewood processor machine.  On July 3, 2020, an employee unjamming a processor machine without it being locked out, received a severe arm injury.
Recent events (2)
  • · I (S) $3398
  • · Z (S) $5398

1910.212 A03 II

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 11, 2020
Abate by
Oct 29, 2020
Penalty
Initial $3,856 · Current $3,080 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    496 Purgatory Rd, Whitinsville, MA:  On July 8, 2020 and at times prior, employees operated an incompletely guarded firewood processor machine and were exposed to crushed-by and amputation injuries in the splitter area during production operations.
Recent events (2)
  • · I (S) $3080
  • · Z (S) $3856

1910.147 C06 II

Other-than-serious 1 instance 5 exposed
Issued
Sep 11, 2020
Abate by
Oct 29, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed.  The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection:    496 Purgatory Rd, Whitinsville, MA: On July 8, 2020 at the start of the inspection, the employer had no documents to certify the accomplishment of the annual periodic inspection that ensured each procedure was inspected for inaccuracies during an actual energy control task.  Additionally, the employer had no documentation for the review, between the inspector and each authorized employee, of that employee's responsibilities each energy control procedure that they were authorized to use.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.147 C07 IV

Other-than-serious 1 instance 14 exposed
Issued
Sep 11, 2020
Abate by
Oct 29, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date.      496 Purgatory Rd, Whitinsville, MA: On July 8, 2020 at the start of the inspection, the employer had no documents to certify that authorized, affected, and other employees had been trained in their energy control responsibilities.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344824289.