HOUSTON, TX ·
OSHA Inspection: GARCIA'S MARBLE & GRANITE FABRICATION
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of GARCIA'S MARBLE & GRANITE FABRICATION in 3509 ELGIN STREET, HOUSTON, TX 77004 (NAICS 327991). OSHA activity number 344831870.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GARCIA'S MARBLE & GRANITE FABRICATION
- Site address
- 3509 ELGIN STREET
- City
- HOUSTON
- State
- TX
- ZIP
- 77004
- Mailing
- 512 COMPTON STREET, ARCOLA, TX 77583
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 3
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.300 B01
- Issued
- Aug 12, 2020
- Abate by
- Sep 8, 2020
- Penalty
- Initial $2,892 · Current $1,735 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) Building 5, a Makita 4.5-inch angle grinder (Model 9564CV, Serial Number 335962A) was missing its guard, exposing employees to amputation hazards.
Recent events (2)
- · I (S) $1735.2
- · Z (S) $2892
1926.405 G02 IV
- Issued
- Aug 12, 2020
- Abate by
- Sep 8, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Building 5, the extension cord powering a Makita 4.5-inch angle grinder (Model 9564CV, Serial Number 335962A) lacked strain relief, exposing covered uninsulated conductors.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1926.416 E01
- Issued
- Aug 12, 2020
- Abate by
- Sep 8, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Building 5, the flexible cord of a Makita 4.5-inch angle grinder (Model 9564CV, Serial Number 335962A) was damaged, exposing uninsulated covered conductors.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 327991)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344831870.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.