Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: RAMONES CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RAMONES CONSTRUCTION, LLC in 808 CLEVELAND BLVD, CALDWELL, ID 83605 (NAICS 238310). OSHA activity number 344835822.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ramones Construction, LLC for free Get an email when a new federal OSHA severe-injury report for Ramones Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
808 CLEVELAND BLVD
City
CALDWELL
State
ID
ZIP
83605
Mailing
17507 MIDLAND BLVD, NAMPA, ID 83687
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
3
Ownership type
Private (A)

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 4 exposed
Issued
Dec 1, 2020
Abate by
Dec 7, 2020
Penalty
Initial $325 · Current $325
29 CFR  1903.19(c)(1):The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  a) The employer has not provided the required certification that all hazards contained in OSHA inspection # 1483582 have been corrected.  This inspection was affirmed as a final order on September 25, 2020, with respect to a workplace located at 808 Cleveland Blvd, Caldwell, ID 83605.      Note) Certification of corrective action is required for this item.
Recent events (1)
  • · Z (O) $325

1926.451 C01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 31, 2020
Abate by
Sep 11, 2020
Penalty
Initial $2,313 · Current $1,738 Reduced
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less:    a) Jobsite, north end of building:  On or about July 15, 2020 and at times prior thereto a single tie-back brace was used to secure a multi-level scaffold system.  The scaffold was 3 feet wide and 5 levels high (between 32 and 35 feet high). The single tie-back was located at approximately 32 feet high from the base of the scaffold.   Note) Certification of corrective action is required for this item.
Recent events (2)
  • · I (S) $1738
  • · Z (S) $2313

1926.454 A

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 31, 2020
Abate by
Sep 25, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:  a) Jobsite, north end of building: On or about July 15, 2020 and at times prior thereto the employer did recognize or acknowledge the hazards of climbing down the cross bracing of a scaffold system.        b) Jobsite, north end of building: On or about July 15, 2020 and at times prior thereto employees did recognize or acknowledge the importance of installing tie-back bracing at the required location(s) on a multi-level scaffold system and the hazards associated with this.    Note) Certification of corrective action is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.501 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 31, 2020
Abate by
Sep 4, 2020
Penalty
Initial $2,313 · Current $1,500 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  a) Jobsite, back side of building: On or about July 15, 2020 and at times prior thereto a wire cable guardrail system was not maintained. The wire cable guardrail system did not extend along the entire edge of the roof deck.    Note) Certification of corrective action is required for this item.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2313

1926.502 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 31, 2020
Abate by
Sep 4, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:  a) Jobsite, back side of building: On or about July 8 and July 15, 2020 a wire cable guard rail system was not maintained.  The wire cable sagged and hung loosely on the posts and below the roof deck.     Note) Certification of corrective action is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344835822.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.