CALDWELL, ID ·
OSHA Inspection: RAMONES CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RAMONES CONSTRUCTION, LLC in 808 CLEVELAND BLVD, CALDWELL, ID 83605 (NAICS 238310). OSHA activity number 344835822.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAMONES CONSTRUCTION, LLC
- Site address
- 808 CLEVELAND BLVD
- City
- CALDWELL
- State
- ID
- ZIP
- 83605
- Mailing
- 17507 MIDLAND BLVD, NAMPA, ID 83687
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 3
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1903.19 C01
- Issued
- Dec 1, 2020
- Abate by
- Dec 7, 2020
- Penalty
- Initial $325 · Current $325
General-duty citation text
29 CFR 1903.19(c)(1):The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) The employer has not provided the required certification that all hazards contained in OSHA inspection # 1483582 have been corrected. This inspection was affirmed as a final order on September 25, 2020, with respect to a workplace located at 808 Cleveland Blvd, Caldwell, ID 83605. Note) Certification of corrective action is required for this item.
Recent events (1)
- · Z (O) $325
1926.451 C01 II
- Issued
- Aug 31, 2020
- Abate by
- Sep 11, 2020
- Penalty
- Initial $2,313 · Current $1,738 Reduced
General-duty citation text
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less: a) Jobsite, north end of building: On or about July 15, 2020 and at times prior thereto a single tie-back brace was used to secure a multi-level scaffold system. The scaffold was 3 feet wide and 5 levels high (between 32 and 35 feet high). The single tie-back was located at approximately 32 feet high from the base of the scaffold. Note) Certification of corrective action is required for this item.
Recent events (2)
- · I (S) $1738
- · Z (S) $2313
1926.454 A
- Issued
- Aug 31, 2020
- Abate by
- Sep 25, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) Jobsite, north end of building: On or about July 15, 2020 and at times prior thereto the employer did recognize or acknowledge the hazards of climbing down the cross bracing of a scaffold system. b) Jobsite, north end of building: On or about July 15, 2020 and at times prior thereto employees did recognize or acknowledge the importance of installing tie-back bracing at the required location(s) on a multi-level scaffold system and the hazards associated with this. Note) Certification of corrective action is required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.501 B01
- Issued
- Aug 31, 2020
- Abate by
- Sep 4, 2020
- Penalty
- Initial $2,313 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Jobsite, back side of building: On or about July 15, 2020 and at times prior thereto a wire cable guardrail system was not maintained. The wire cable guardrail system did not extend along the entire edge of the roof deck. Note) Certification of corrective action is required for this item.
Recent events (2)
- · I (S) $1500
- · Z (S) $2313
1926.502 B01
- Issued
- Aug 31, 2020
- Abate by
- Sep 4, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: a) Jobsite, back side of building: On or about July 8 and July 15, 2020 a wire cable guard rail system was not maintained. The wire cable sagged and hung loosely on the posts and below the roof deck. Note) Certification of corrective action is required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 238310)