AMBRIDGE, PA ·
OSHA Inspection: SUKUP STEEL STRUCTURES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUKUP STEEL STRUCTURES in 360 14TH STREET, AMBRIDGE, PA 15003 (NAICS 331110). OSHA activity number 344846779.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUKUP STEEL STRUCTURES
- Site address
- 360 14TH STREET
- City
- AMBRIDGE
- State
- PA
- ZIP
- 15003
- Mailing
- 360 14TH STREET, AMBRIDGE, PA 15003
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331110
- Employees
- 125
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C01
- Issued
- Sep 18, 2020
- Penalty
- Initial $13,359 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Facility: On or about July 16, 2020, there were two authorized employees working on the standing seam roof machine (SSR) and the machine was not locked out nor tagged out by either employee. The employees had removed 4 guards and were working past where the guards were to do their work.
Recent events (2)
- · I (S) $0
- · Z (S) $13359
1910.147 F01 II
- Issued
- Sep 18, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(1)(ii): Employees were not removed from the machine or equipment area in accordance with paragraph (e)(2) of this section during testing or positioning of machines, equipment or components thereof. (a) Facility: On or about July 16, 2020, the two authorized employees did not ensure that all employees were removed from the work area before jogging the machine (to help set it up).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 C07 III B
- Issued
- Sep 18, 2020
- Penalty
- Initial $0 · Current $6,680
General-duty citation text
29 CFR 1910.147(c)(7)(iii)(B): Additional retraining was not provided whenever a periodic inspection under 29 CFR 1910.147(c)(6) revealed that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures: (a) Facility: On or about July 16, 2020, two authorized employees were working on a machine (standing seam metal roof) and it was not locked nor tagged out. These two authorized employees had removed 4 panel guards to the machine and were working inside the area of the removed guards. These two authorized employees need to be retrained in the proper procedures of lockout/tagout.
Recent events (2)
- · I (O) $6680
- · Z (S) $0
More inspections in this industry (NAICS 331110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344846779.