Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KEVIN HUGHES CONSTRUCTION CO. INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KEVIN HUGHES CONSTRUCTION CO. INC. in 290 EASTERN BLVD, CANANDAIGUA, NY 14424 (NAICS 238190). OSHA activity number 344852223.

Watch Kevin Hughes Construction CO. INC. — free Get an email when a new federal OSHA severe-injury report for Kevin Hughes Construction CO. INC. is published. One employer, no account, unsubscribe in one click.
Site address
290 EASTERN BLVD
City
CANANDAIGUA
State
NY
ZIP
14424
Mailing
4 RIVERSIDE DRIVE, UTICA, NY 13502
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.153 J

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $4241.00 · Current $2756.00 Reduced
29 CFR 1926.153(j): Container(s) of liquefied petroleum gas (LP-Gas) were stored within building.  a) At the jobsite, inside the building, on or about 7/24/20:  LP Gas was stored inside the building for use with a barbecue grill.
Recent events (2)
  • — I (S) $2756
  • — Z (S) $4241

1926.451 E01

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2545.00 · Current $0.00 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  a) At the jobsite, accessing the roof, on or about 7/24/20:  Employees used a scissor lift to gain access and egress from the roof where the lift was parked parallel to the building and workers were forced to climb over the railings.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2545

1926.503 A02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4241.00 · Current $2756.00 Reduced
29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii)  a) At the jobsite,  on or about 7/17/20:  Employees were installing sheathing onto a flat roof system of trusses, 17 feet from grade (by plan) without fall protection of any kind while under the direct supervision of the Foreman who was identified as the competent person.
Recent events (2)
  • — I (S) $2756
  • — Z (S) $4241

1926.501 B02 I

Repeat Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $11875.00 · Current $6617.00 Reduced
29 CFR 1926.501(b)(2)(i): Each employee who was constructing a leading edge 6 feet or more above lower levels was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems:  a) At the jobsite,  on or about 7/17/20:  Employees were installing sheathing onto a flat roof system of trusses, 17 feet from grade (by plan) without fall protection of any kind.       Kevin Hughes Construction Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.501(b)(1), which was contained in OSHA inspection number 1148927 citation number 1 item number 4  and was affirmed as a final order on 11/7/16, with respect to a workplace located at Homewood Suites, 201 Woods Park Drive, New Hartford, NY  13143.
Recent events (2)
  • — I (R) $6617
  • — Z (R) $11875

1926.404 B01 I

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:  a) At the jobsite, inside the building, on or about 7/24/20:  Employees were using battery chargers and a Dewalt chop-saw, powered with a 7500 watt Honda Gen-Pro generator without ground fault protection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344852223.