Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: STUCCO & BEYOND INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STUCCO & BEYOND INC. in 942 PITNER AVE., EVANSTON, IL 60202 (NAICS 238140). OSHA activity number 344860127.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stucco & Beyond INC. for free Get an email when a new federal OSHA severe-injury report for Stucco & Beyond INC. is published. One employer, no account, unsubscribe in one click.
Site address
942 PITNER AVE.
City
EVANSTON
State
IL
ZIP
60202
Mailing
1686 ASH ST., DES PLAINES, IL 60018
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
Private (A)

2 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 24, 2020
Penalty
Initial $4,048 · Current $4,000 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds were not fully planked or decked between the front uprights and the guardrail supports:    a) On July 29, 2020, employees were exposed to the hazard of falling up to approximately 23 feet from tubular welded frame scaffold platforms which were not fully planked
Recent events (2)
  • · I (S) $4000
  • · Z (S) $4048

1926.451 F06

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 24, 2020
Penalty
Initial $4,048 · Current $0 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).     a) On July 29, 2020, employees were performing masonry work from a tubular welded framed scaffold that was less than 10 feet from an energized power service of 120/240v.