Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VINYL MASTER HOME IMPROVEMENT LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VINYL MASTER HOME IMPROVEMENT LLC in 51 PIERREPONT AVE, RUTHERFORD, NJ 07070 (NAICS 236118). OSHA activity number 344864293.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vinyl Master Home Improvement LLC — free Get an email when a new federal OSHA severe-injury report for Vinyl Master Home Improvement LLC is published. One employer, no account, unsubscribe in one click.
Site address
51 PIERREPONT AVE
City
RUTHERFORD
State
NJ
ZIP
07070
Mailing
55 ADAMS STREET, CLIFTON, NJ 07011
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 25, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:   a- (Building Exterior): Employees engaged in roofing activities on a 8 on 12 pitched roof were exposed to fall hazards of approximately 16ft to the ground below as a means of fall protection had not been utilized. Condition noted or about 08/01/2020.
Recent events (1)
  • — Z (S) $4048

1926.1053 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 25, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:(a)   a- (Building Exterior): Employees engaged in roofing activities on a 8 on 12 pitched roof were exposed to fall hazards of approximately 16ft to the ground below as a ladder used for roof access whose side rails did not extend 3ft above the upper landing surface Condition noted or about 08/01/2020.
Recent events (1)
  • — Z (S) $4048

View Vinyl Master Home Improvement LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344864293.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.