Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: POWER HOME EXTERIORS, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of POWER HOME EXTERIORS, INC in 2126 E LAKESHORE DR., TWIN LAKES, WI 53181 (NAICS 238160). OSHA activity number 344867312.

Watch Power Home Exteriors, INC — free Get an email when a new federal OSHA severe-injury report for Power Home Exteriors, INC is published. One employer, no account, unsubscribe in one click.
Site address
2126 E LAKESHORE DR.
City
TWIN LAKES
State
WI
ZIP
53181
Mailing
926 S. WEST ST., WAUKEGAN, IL 60085
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

4 citations on file for this inspection.

1903.19 D01

Other-than-serious 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $325.00 · Current $325.00
29 CFR  1903.19(d)(1):The employer did not submit to the Agency documents demonstrating that abatement is complete for each serious violation for which the Agency indicates in the citation that such abatement documentation is required.  (a)  The employer failed to provide documentation to the Agency demonstrating that abatement is completed for the serious violations that were issued by the Agency.
Recent events (1)
  • — Z (O) $325

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4048.00 · Current $4048.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   (a) On or about August 04, 2020, employees conducting roofing work on an 5:12 pitch roof were not protected from falling to the lower level. This exposed employees to a fall hazard of approximately 13 feet on the West and North sides of the structure and approximately 25 feet on the South side of the structure.
Recent events (1)
  • — Z (S) $4048

1926.503 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1735.00 · Current $1735.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  (a)  On or about August 04, 2020, the employer did not ensure that employees exposed to potential fall hazards had been trained to recognize and minimize the fall hazards associated with their work.
Recent events (1)
  • — Z (S) $1735

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2313.00 · Current $2313.00
29 CFR 1926.1053(b)(1): Where a portable ladder(s) was used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.    (a) On or about August 04, 2020, the  extension ladder erected on the North side of the structure, and being used for access to the roof, did not extend at least three (3) feet above the edge, and/or was not secured to the structure when it was not extended three feet above the landing surface.
Recent events (1)
  • — Z (S) $2313

View POWER HOME EXTERIORS, INC's full OSHA safety record →