PARK RIDGE, IL —
OSHA Inspection: POWER HOME EXTERIORS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of POWER HOME EXTERIORS, INC. in 250 W CUTTRISS AVE., PARK RIDGE, IL 60068 (NAICS 238160). OSHA activity number 345270052.
Where did this inspection happen?
- Establishment
- POWER HOME EXTERIORS, INC.
- Site address
- 250 W CUTTRISS AVE.
- City
- PARK RIDGE
- State
- IL
- ZIP
- 60068
- Mailing
- 926 S. WEST AVE., WAUKEGAN, IL 60085
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.100 A
- Issued
- Penalty
- Initial $2575.00 · Current $2575.00
General-duty citation text
29 CFR 1926.100(a):Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) On April 22, 2021, at the above addressed jobsite, employees were exposed to a struck-by hazard from falling slate, tools, and debris when working below employees. The employees were not wearing hard hats. No abatement certification or documentation is required for this item.
Recent events (1)
- — Z (S) $2575
1926.1053 B22
- Issued
- Penalty
- Initial $4505.00 · Current $4505.00
General-duty citation text
29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall: a) On April 22, 2021, at the above addressed jobsite employees were exposed to fall hazards while carrying tools and materials up an extension ladder. No abatement certification or documentation is required for this item.
Recent events (1)
- — Z (S) $4505
1926.1053 B01
- Issued
- Penalty
- Initial $3218.00 · Current $3218.00
General-duty citation text
29 CFR 1926.1053(b)(1):Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On April 22, 2021, employee(s) were observed utilizing a ladder that did not extend at least three (3) feet above the upper landing of the working platform. No abatement certification or documentation is required for this item.
Recent events (1)
- — Z (S) $3218
1926.501 B13
- Issued
- Penalty
- Initial $22527.00 · Current $22527.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) On or about April 22, 2021, On April 22, 2021, at the above addressed jobsite, employees conducting roofing work on a two story residential home, at approximately twenty (20') feet above the ground, were not provided personal fall arrest systems or other means of fall protection, thereby exposing employees to fall hazards. No abatement certification or documentation required for this violation. Power Home Exteriors, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501 (b)(13) which was contained in OSHA inspection number 1499930, citation 2, item 1, and was affirmed as a final order on February 12, 2021, with respect to a worksite located at 2709-2719 Langley Circle, in Glenview, Illinois. Power Home Exteriors, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501 (b)(13) which was contained in OSHA inspection number 1486731, citation 1, item 1, and was affirmed as a final order on October 21, 2020, with respect to a worksite located at 2126 E. Lakeshore Drive, in Twin Lakes, Wisconsin.
Recent events (1)
- — Z (R) $22527
More inspections at POWER HOME EXTERIORS, INC.
GLENVIEW, IL—2020-10-27 00:00:00
POWER HOME EXTERIORS, INC.
TWIN LAKES, WI—2020-08-04 00:00:00
POWER HOME EXTERIORS, INC
View POWER HOME EXTERIORS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source