MIDDLETON, WI ·
OSHA Inspection: H.J. PERTZBORN PLUMBING AND FIRE PROTECTION CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of H.J. PERTZBORN PLUMBING AND FIRE PROTECTION CORPORATION in 7425 UNIVERSITY AVENUE, MIDDLETON, WI 53562 (NAICS 238220). OSHA activity number 344869714.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 7425 UNIVERSITY AVENUE
- City
- MIDDLETON
- State
- WI
- ZIP
- 53562
- Mailing
- 802 JOHN NOLEN DRIVE, MADISON, WI 53713
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 3
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.1060 A01 III
- Issued
- Sep 11, 2020
- Abate by
- Oct 30, 2020
- Penalty
- Initial $2,925 · Current $2,633 Reduced
General-duty citation text
29 CFR 1926.1060(a)(1)(iii): The proper construction, use, placement, and care in handling of all stairways and ladders; On or about August 6, 2020, at the previously addressed job site, the employer did not ensure the use of an appropriate ladder or other safe means of egress while employees were working to repair/replace a water line in a trench at a depth ranging from 5-6 feet. Employees worked in the trench with a ladder laying on the ground outside of the trench which did not provide safe and immediate means of egress.
Recent events (2)
- · I (O) $2633
- · Z (S) $2925
1926.651 J02
- Issued
- Sep 11, 2020
- Penalty
- Initial $3,441 · Current $3,097 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. On or about August 6, 2020, at the previously addressed job site, the east side spoil pile was not at least 2 feet from the edge of the excavation. There is no abatement certification or documentation required for this item.
Recent events (2)
- · I (O) $3097
- · Z (S) $3441
1926.652 A01
- Issued
- Sep 11, 2020
- Penalty
- Initial $4,875 · Current $4,387 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). On or about August 6, 2020, at the previously addressed job site, workers were not protected by properly sloping the sides or using appropriate protective systems such as a trench box or shoring while working to repair/replace a section of water line in a trench at a depth ranging from 5-6 feet with vertical walls. There is no abatement certification or documentation required for this item.