OSHA Inspection: NATIONWIDE MASONS CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NATIONWIDE MASONS CONSTRUCTION, INC. in 516 PARK AVENUE, YONKERS, NY 10703 (NAICS 238160). OSHA activity number 344876453.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nationwide Masons Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Nationwide Masons Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
516 PARK AVENUE
City
YONKERS
State
NY
ZIP
10703
Mailing
30 WEST 47TH STREET, NEW YORK, NY 10036
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 16, 2020
Penalty
Initial $3,084 · Current $3,084
29 CFR 1926.100(a):   Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:   A) Exterior on the ground: An employee was exposed to head injuries while working below other employees that were conducting roofing work above. The employee was not protected by a hard hat or protective helmet, on or about March 8th, 2020.   NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $3084

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 16, 2020
Penalty
Initial $4,626 · Current $4,626
29 CFR 1926.102(a)(1):     Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.                                                                                           A) Exterior, On the roof: Employees were exposed to eye/face injuries while using pneumatic nail guns and were not protected with any type of eye/face protection, on or about July 17th, 2020.    NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this  violation as normally required by 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4626

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 16, 2020
Penalty
Initial $5,398 · Current $5,398
29 CFR 1926.501(b)(13):   Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    A) Roof of the structure: Employees were exposed to fall hazards of approximately 21 feet while engaged in roofing work on the roof of a structure without a means of fall protection in place, on or about July 17th, 2020.   NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $5398

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 16, 2020
Penalty
Initial $5,398 · Current $5,398
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    A) Exterior, Front of the house: Employees were exposed to fall hazards of approximately 21 feet while using an extension ladder that was not extended at least 3 feet over the landing that they were accessing, on or about July 17th, 2020.    NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $5398

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344876453.