SADORUS, IL ·
OSHA Inspection: DEEDRICK PRECISION MACHINING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DEEDRICK PRECISION MACHINING, INC. in 105 E MARKET STREET, SADORUS, IL 61872 (NAICS 332710). OSHA activity number 344878517.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DEEDRICK PRECISION MACHINING, INC.
- Site address
- 105 E MARKET STREET
- City
- SADORUS
- State
- IL
- ZIP
- 61872
- Mailing
- P.O. BOX 50, SADORUS, IL 61872
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 14
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
1910.147 C04 II
- Issued
- Dec 31, 2020
- Abate by
- Feb 12, 2021
- Penalty
- Initial $3,856 · Current $2,315 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: On or about August 12, 2020, employees were exposed to caught-in and amputation hazards from performing servicing and maintenance activities, and the employer did not developed specific procedures that outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy. The procedures shall clearly outline: a. A specific statement of the intended use of the procedure, b. Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy, c. Specific procedural steps for the placement, removal and transfer of lockout devices and the responsibility for them, and d. Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
Recent events (2)
- · I (S) $2315
- · Z (S) $3856
More inspections in this industry (NAICS 332710)