Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: OSCAR FIGUEROA, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OSCAR FIGUEROA, LLC. in 6859 JEFFERSON HWY., BATON ROUGE, LA 70806 (NAICS 236220). OSHA activity number 344881917.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Oscar Figueroa, LLC. for free Get an email when a new federal OSHA severe-injury report for Oscar Figueroa, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
6859 JEFFERSON HWY.
City
BATON ROUGE
State
LA
ZIP
70806
Mailing
3655 DONALDSON DR., BATON ROUGE, LA 70814
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
14
Ownership type
Private (A)

6 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 17, 2020
Abate by
Oct 2, 2020
Penalty
Initial $3,856 · Current $3,856
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles.   a) On or about August 12, 2020, on the West side of the building, an employee was operating a Husqvarna MS 360 masonry saw, cutting bricks without wearing eye protection.
Recent events (1)
  • · Z (S) $3856

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 17, 2020
Abate by
Oct 2, 2020
Penalty
Initial $3,856 · Current $3,856
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level.  a) On or about August 12, 2020, on the west side of the building, employees were applying bricks to the outer shell of the building on a Scaffold at an elevated height of approximately ten (10) feet without a harness for fall protection.
Recent events (1)
  • · Z (S) $3856

1926.451 G01 V

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 17, 2020
Abate by
Oct 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1)(v): Each employee on a walkway located within a scaffold was not protected by a guardrail system (with a minimum 200 pound toprail capacity) installed within 9.5 inches (24.1 cm) of and along at least one side of the walkway.  a) On or about August 12, 2020, on the west side of the building, employees were applying bricks to the outer shell of the building on a Scaffold at an elevated height of approximately ten (10) feet without guardrails or any fall protection.
Recent events (1)
  • · Z (S) $0

1926.451 G01 VI

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 17, 2020
Abate by
Oct 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1)(vi): Each employee performing overhand bricklaying operations from a supported scaffold was not protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity).  a) On or about August 12, 2020, on the west side of the building, employees were applying bricks to the outer shell of the building on a Scaffold at an elevated height of approximately ten (10) feet without end rails/guardrails or any fall protection.
Recent events (1)
  • · Z (S) $0

1926.405 G02 IV

Other-than-serious 1 instance 1 exposed
Issued
Sep 17, 2020
Abate by
Oct 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws.  a) On or about August 12, 2020, on the West side of the building, an employee was operating a Husqarvana MS 360 Masonry Saw with strain relief not fully attached and had pulled away from receptacle.
Recent events (1)
  • · Z (O) $0

1926.416 E01

Other-than-serious 1 instance 1 exposed
Issued
Sep 17, 2020
Abate by
Oct 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used.  a) On or about August 12, 2020, on the West side of the building, employees were operating a Husqvarna MS 360 Masonry Tile Saw that was connected to an electrical power cord with damaged outer sheathing.
Recent events (1)
  • · Z (O) $0

View Oscar Figueroa, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344881917.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.