HASLET, TX —
OSHA Inspection: ADALBERTO MONTOYA DELGADO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADALBERTO MONTOYA DELGADO in 12360 STOWERS TRL, HASLET, TX 76052 (NAICS 238140). OSHA activity number 344883236.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADALBERTO MONTOYA DELGADO
- Site address
- 12360 STOWERS TRL
- City
- HASLET
- State
- TX
- ZIP
- 76052
- Mailing
- 2906 AVE J, FORT WORTH, TX 76105
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Aug 26, 2020
- Penalty
- Initial $1,475 · Current $1,475
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolding was not fully planked or decked. On the south side of the construction site, employees working from a tubular welded frame scaffold that was not fully planked on all working levels were exposed to falling hazards.
Recent events (1)
- — Z (S) $1475
1926.451 E01
- Issued
- Aug 26, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. On the south side of the construction site, the employer did not provide a scaffold ladder where employees could access and egress the tubular welded frame scaffold safely, exposing them to fall hazards.
Recent events (1)
- — Z (S) $0
1926.451 G01
- Issued
- Aug 26, 2020
- Penalty
- Initial $1,966 · Current $1,966
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: On the south side of the construction site, employees were observe working from the second tier tubular welded frame scaffold without a fall protective system while performing masonry work. The employees were exposed to a fall hazard of 13 feet to the ground below.
Recent events (1)
- — Z (S) $1966
1926.451 H01
- Issued
- Aug 26, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects. For falling objects too large, heavy or massive to be contained or deflected, the employer did not place and secure such potential falling objects away from the edge of the surface from which they could fall. On the south side of the construction site, employees working from a tubular welded frame scaffold without toe boards being installed were exposed to falling objects.
Recent events (1)
- — Z (S) $0
1926.454 A
- Issued
- Aug 26, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. On the south side of the construction site, the employer did not provided training on the tubular welded frame scaffold to recognize and avoid fall hazards prior to installing masonry material from the two tier scaffold.
Recent events (1)
- — Z (O) $0
More inspections at Adalberto Montoya Delgado
View Adalberto Montoya Delgado's full OSHA safety record →