NEW YORK, NY ·
OSHA Inspection: ALL DIMENSION CONSTRUCTION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ALL DIMENSION CONSTRUCTION in 165 WILLIAM ST, NEW YORK, NY 10038 (NAICS 236210). OSHA activity number 344885611.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALL DIMENSION CONSTRUCTION
- Site address
- 165 WILLIAM ST
- City
- NEW YORK
- State
- NY
- ZIP
- 10038
- Mailing
- 12 GRUBER DRIVE, GLEN COVE, NY 11542
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236210
- Employees
- 22
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.405 J01 I
- Issued
- Dec 9, 2020
- Penalty
- Initial $3,856 · Current $3,856
General-duty citation text
29 CFR 1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact:( a) Employees were exposed to electric shock hazard; there was an exposed live wire tip/terminal screw on the wall mounted light switch inside the doorway to the construction area, the elevator motor room (roof house); the light switch box did not have a cover and there was access to the live wire terminal screws. Location: 165 William St, NY NY 10038 On or about 8-13-2020 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (1)
- · Z (S) $3856
1926.405 G02 IV
- Issued
- Dec 9, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv):Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Employees were exposed to electric shock hazard due to damaged wiring; the metal conduit wire covering was separated exposing the inner wires to sharp edges/damage; on wiring located over the door to the elevator roof house. Location: 165 William St, NY NY 10038 On or about 8-13-2020 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (1)
- · Z (S) $0
1926.451 B04
- Issued
- Dec 9, 2020
- Penalty
- Initial $3,856 · Current $3,856
General-duty citation text
29 CFR 1926.451(b)(4): Employer did not ensure that: Each end of a scaffold platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm). a) Employers suspended scaffold platform extended only 3 inches over its support point due to being obstructed by the roof railing; was used for work on the elevator roof house, elevation 10 stories. Employees were exposed to scaffold collapse hazard. Location: 165 William St, NY NY 10038 On or about 8-13-2020 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (1)
- · Z (S) $3856
1926.451 B10
- Issued
- Dec 9, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(10): Scaffold components manufactured by different manufacturers shall not be intermixed unless the components fit together without force and the scaffold's structural integrity is maintained by the user. Scaffold components manufactured by different manufacturers shall not be modified in order to intermix them unless a competent person determines the resulting scaffold is structurally sound. a) The employer modified scaffold uses/types; employer attached a suspended scaffold work platform to a pipe scaffold frame standing next to (tied to) the railing at the edge of the roof; elevation 10 stories. The scaffold components were not secured/ used as designed; employees were exposed to scaffold collapse hazard when rebuilding the elevator roof house. Location: 165 William St, NY NY 10038 On or about 8-13-2020 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (1)
- · Z (S) $0
1926.451 F07
- Issued
- Dec 9, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7):Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) The employer used a scaffold made from parts of different type of scaffolds tied together at the roof edge; employees were exposed to scaffold collapse hazard when rebuilding the elevator roof house; elevation 10 stories. --- suspended scaffold work platform was tied to a pipe scaffold frame, not supported as designed; --- suspended scaffold stirrup/guardrails were not supported as designed; Location: 165 William St, NY NY 10038 On or about 8-13-2020 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (1)
- · Z (S) $0
5(a)(1)
- Issued
- Dec 9, 2020
- Abate by
- Jan 6, 2021
- Penalty
- Initial $3,856 · Current $3,856
General-duty citation text
29 CFR OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were not protected from the hazard struck by/crush hazard by an elevator which was not locked out. a) Employees were exposed to struck-by/ caught-by hazard from sudden start-up of the elevator machine (pulleys and cables) due to the elevator not being shut down or guarded during rebuilding of the elevator motor roof house. Location: 165 William St, NY NY 10038 On or about 8-13-2020
Recent events (1)
- · Z (S) $3856
More inspections in this industry (NAICS 236210)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344885611.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.