Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NOBLE ENVIRONMENTAL INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NOBLE ENVIRONMENTAL INC. in 111 CONNER LANE, BELLE VERNON, PA 15012 (NAICS 562212). OSHA activity number 344899901.

Watch Noble Environmental INC. — free Get an email when a new federal OSHA severe-injury report for Noble Environmental INC. is published. One employer, no account, unsubscribe in one click.
Site address
111 CONNER LANE
City
BELLE VERNON
State
PA
ZIP
15012
Mailing
111 CONNER LANE, BELLE VERNON, PA 15012
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562212
Employees
15
Ownership type
A

6 citations on file for this inspection.

1926.95 A

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $8096.00 · Current $4100.00 Reduced
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided:  a)  At the worksite, on or about August 26, 2020 -  Employees were not provided with adequate personal protective equipment such as, but not limited to, safety glasses/face shield, and flame retardant clothing during pipe cutting operations.
Recent events (2)
  • — I (S) $4100
  • — Z (S) $8096

1926.651 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $6747.00 · Current $3400.00 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:  a)  At the worksite, on or about August 26, 2020 - Protection was not provided by placing or keeping excavated materials at least 2 (.61m) from the edge of excavations.  The spoil pile was on the edge of the trench excavation.  Employees were in a 7.5 feet deep during pipe cutting operations.
Recent events (2)
  • — I (S) $3400
  • — Z (S) $6747

1926.651 K01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems:  a)  At the worksite, on or about August 26, 2020 - A daily inspection of the excavation were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins.  Employees worked in a 7.5 foot deep trench excavation during pipe cutting operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.652 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $6747.00 · Current $3400.00 Reduced

Hazardous substances S777

29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):  a)  At the worksite, on or about August 26, 2020 -  An adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c) was not used to protect each employee in an excavation.  Employees were working in an approximately 7.5 feet deep unprotected trench.
Recent events (2)
  • — I (S) $3400
  • — Z (S) $6747

1926.651 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  a)  At the worksite, on or about August 26, 2020 - A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet or more in depth.  Employees were working in a 7.5 feet deep trench excavation without a stair way, ladder, ramp or other safe means of egress.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $8096.00 · Current $4100.00 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59)  a)  At the worksite, on or about August 26, 2020 - Employees were not provided effective information and training on hazardous chemical in their work area at the time of their initial assignment.  Employees were exposed to methane, a flammable, during pipe cutting operations.
Recent events (2)
  • — I (O) $4100
  • — Z (S) $8096

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344899901.