Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: HANS SIDING

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of HANS SIDING in 2163 ULSTER ST., DENVER, CO 80238 (NAICS 238170). OSHA activity number 344903349.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hans Siding for free Get an email when a new federal OSHA severe-injury report for Hans Siding is published. One employer, no account, unsubscribe in one click.
Establishment
HANS SIDING
Site address
2163 ULSTER ST.
City
DENVER
State
CO
ZIP
80238
Mailing
964 S. RICHFIELD WAY, AURORA, CO 80017
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
1
Ownership type
Private (A)

3 citations on file for this inspection.

1926.20 B02

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Dec 31, 2020
Abate by
Feb 5, 2021
Penalty
Initial $2,892 · Current $0 Reduced
29 CFR  1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):  (a) Hans Siding at 2163 Ulster Street, Denver, CO: On and around August 14, 2020, the controlling employer did not designate a competent person to make frequent and regular inspections of the job sites, materials, and equipment to ensure that subcontractors had developed and implemented Specified Exposure Control Methods or Alternate Exposure Control Methods and established a written exposure control plan, when subcontractor employees were exposed to airborne crystalline silica hazards by work tasks. Subcontractor employees cut Exterior Fiber-Cement, and 2X Hardie Trim Siding, containing silica, with a hand saw but had not developed and implemented Specified Exposure Control Methods in that the hand saw did not have a dust collection system to comply with Table 1 Entry iii or Alternate Exposure Control Methods in that the subcontractors had not conducted exposure assessments to determine subcontractor employee exposure to silica. The subcontractors had not developed written exposure control plans for the tasks. This condition exposed subcontractor employees to airborne crystalline silica hazards.   Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $0
  • · Z (S) $2892

1910.1200 E01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Dec 31, 2020
Abate by
Feb 5, 2021
Penalty
Initial $2,892 · Current $0 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program including the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):  (a) Hans Siding at 2163 Ulster Street, Denver, CO: On and around August 14, 2020, the exposing employer did not develop, implement, and maintain at the workplace a site specific written hazard communication program. An employees were potentially exposed to hazardous chemicals, including but not limited to the following:   1) Perm-a-barrier WB Primer, containing vinyl acetate 2) Exterior Fiber-Cement, containing quartz silica 3) 2X Hardie Trim, containing quartz silica   Note: The requirements applicable to the construction standard under this section are identical to other set forth in 29 CFR 1926.59.  Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $0
  • · Z (S) $2892

1910.1200 H01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Dec 31, 2020
Abate by
Feb 5, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) Hans Siding at 2163 Ulster Street, Denver, CO: On and around August 14, 2020, the exposing employer did not provide employees with effective information and training on hazardous chemicals in their work area.  Employees did not know the hazards of the chemicals in their work areas. This condition exposed employees to chemical hazards, including but not limited to Perm-a-barrier WB Primer, containing vinyl acetate; Exterior Fiber-Cement, containing quartz silica; and 2X Hardie Trim, containing quartz silica.   Abatement Note: Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.  Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344903349.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.