On , OSHA opened a referral safety inspection of SAMBA CONSTRUCTION INC. in THE GOVERNORS DEVELOPMENT LOT 54 TEMPLE ROAD, LEWES, DE 19958 (NAICS 236115). OSHA activity number 344904826.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAMBA CONSTRUCTION INC.
- Site address
- THE GOVERNORS DEVELOPMENT LOT 54 TEMPLE ROAD
- City
- LEWES
- State
- DE
- ZIP
- 19958
- Mailing
- 90 VINCENT STREET, NEWARK, NJ 07105
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 10
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Feb 24, 2021
- Penalty
- Initial $3,686 · Current $3,686
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by a guardrail system, safety net system, or personal fall arrest system, or an alternative fall protection measure that meets a provision described in paragraph (b) of this section: a) The Governors Development Lot 54, Temple Road, Lewes, DE 19958: On or about August 28, 2020, the employer failed to ensure framers used fall protection while working at least 20 feet or more above lower levels.
Recent events (1)
- · Z (S) $3686
1926.1053 B01
- Issued
- Feb 24, 2021
- Penalty
- Initial $2,633 · Current $2,633
General-duty citation text
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access. a) Governors Development Lot 54, Temple Road, Lewes, DE 19958: On or about August 28, 2020, the employer did not make sure framers used Werner aluminum extension ladders that extended at least three feet above the upper landing to gain roof access.