Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAGNODE CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MAGNODE CORPORATION in 400 E STATE ST, TRENTON, OH 45067 (NAICS 331318). OSHA activity number 344904842.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Magnode Corporation — free Get an email when a new federal OSHA severe-injury report for Magnode Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
MAGNODE CORPORATION
Site address
400 E STATE ST
City
TRENTON
State
OH
ZIP
45067
Mailing
400 E STATE ST, TRENTON, OH 45067
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331318
Employees
206
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 7 exposed
Issued
Dec 2, 2020
Abate by
Jan 6, 2021
Penalty
Initial $13,494 · Current $9,400 Reduced
29 CFR 1910.147(c)(4)(i):Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.    a) On or about August 24, 2020, the employer had not required an energy control procedure to be utilized when performing maintenance on items such as but not limited to changing rollers on the rear/back clamp of saw 051, a Metl Cutoff Saw Model CS3-26-T8.
Recent events (2)
  • — I (S) $9400
  • — Z (S) $13494

1910.147 C07 I A

Serious Gravity 10 1 instance 7 exposed
Issued
Dec 2, 2020
Abate by
Jan 6, 2021
Penalty
Initial $13,494 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.    a) On or about August 24, 2020, the employer provided inadequate training to authorized employees for saw 051, a Metl Cutoff Saw Model CS3-26-T8, as authorized employees were not trained to isolate and control the energy when changing the rollers on the rear/back clamp.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13494

1910.147 C06 II

Deleted Serious Gravity 10 1 instance 7 exposed
Issued
Dec 2, 2020
Abate by
Jan 6, 2021
Penalty
Initial $13,494 · Current $0 Reduced
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection   a) On or about November 6, 2020, the employer had not certified that an inspection of the hazardous energy control procedure for equipment such as but not limited to saw 051, a Metl Cutoff Saw Model CS3-26-T8, as no authorized employees took part in the inspection, utilized the procedure being inspection, and the deviations and inadequacies of the procedure were not identified.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13494

1910.147 D

Deleted Serious Gravity 10 1 instance 7 exposed
Issued
Dec 2, 2020
Abate by
Jan 6, 2021
Penalty
Initial $13,494 · Current $0 Reduced
29 CFR  1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.    a) On or about August 24, 2020, the employer had not required the application of lockout and tagout devices to control and isolate energy (mechanical and pneumatic) when performing maintenance on items such as but not limited to changing rollers on the rear/back clamp of saw 051, a Metl Cutoff Saw Model CS3-26-T8.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13494

1910.212 A01

Deleted Serious Gravity 10 1 instance 7 exposed
Issued
Dec 2, 2020
Abate by
Jan 6, 2021
Penalty
Initial $13,494 · Current $0 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.   a) On or about August 24, 2020, the interlock gate guarding the point of operation area of saw 051, a Metl Cutoff Saw Model CS3-26-T8, was not adequate.  Employees had been trained to circumvent the interlock gate by entering the gated area and closing the door behind them, and there was no safety switch on the interlock gate to be reset for energization of the saw.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13494

View Magnode Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344904842.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.