OSHA Inspection: DANON GROUP

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of DANON GROUP in 12-38 RIVER RD, FAIR LAWN, NJ 07410 (NAICS 236116). OSHA activity number 344909114.

Watch Danon Group — free Get an email when a new federal OSHA severe-injury report for Danon Group is published. One employer, no account, unsubscribe in one click.
Establishment
DANON GROUP
Site address
12-38 RIVER RD
City
FAIR LAWN
State
NJ
ZIP
07410
Mailing
15 BIGMAN PL, FAIR LAWN, NJ 07410
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.451 F06

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $4096.00 · Current $4096.00
29 CFR  1926.451(f)(6):Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).  The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:*Insulated Lines   300 volts to 50 kv.  10 feet (3.1 m)   Exception to paragraph (f)(6): Scaffolds and materials may be closer to power lines than specified above where such clearance is necessary for performance of work, and only after the utility company, or electrical system operator, has been notified of the need to work closer and the utility company, or electrical system operator, has deenergized the lines, relocated the lines, or installed protective coverings to prevent accidental contact with the lines.  a) Exterior - Front: workers were exposed to electric hazards while installing waterproof membrane from a pump jack scaffold platform that was approximately 8.5 feet from a 26KVA/13KVA primary line, on or about 8/28/20
Recent events (1)
  • — Z (S) $4096

1926.1052 C01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1755.00 · Current $1755.00
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  a) Interior Stairway to 1st Floor - Employees were exposed to fall hazards of approximately 4 feet while accessing the 1st floor framing deck utilizing a wood stairway without any handrail, on or about 8/28/20.
Recent events (1)
  • — Z (S) $1755

1926.1052 C01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  a) Interior Stairway to 1st floor: Employees were exposed to fall hazards of approximately 4 feet, while accessing the 1st floor deck utilizing wood stairway without any handrails and an exposed side, on or about 8/28/20.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344909114.