Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: OLIVER TOLAS HEALTHCARE PACKAGING LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OLIVER TOLAS HEALTHCARE PACKAGING LLC in 905 PENNSYLVANIA BLVD, FEASTERVILLE TREVOSE, PA 19053 (NAICS 561910). OSHA activity number 344912878.

Watch Oliver Tolas Healthcare Packaging LLC — free Get an email when a new federal OSHA severe-injury report for Oliver Tolas Healthcare Packaging LLC is published. One employer, no account, unsubscribe in one click.
Site address
905 PENNSYLVANIA BLVD
City
FEASTERVILLE TREVOSE
State
PA
ZIP
19053
Mailing
905 PENNSYLVANIA BLVD, FEASTERVILLE TREVOSE, PA 19053
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561910
Employees
204
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $13653.00 · Current $13653.00
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   a)  Worksite - On or about September 3, 2020, the Standford Roll Doctor machine was not guarded to prevent employees from becoming caught in the moving parts.  No abatement certification or documentation required
Recent events (1)
  • — Z (S) $13653

1910.219 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:  a)  Worksite - On or about September 3, 2020, the Standford Roll Label Doctor machine has an exposed rotating shaft with an unsmooth end and was not provided with a nonrotating cap or sleeve.  No abatement certification or documentation required
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344912878.