Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: GENERAL SHOE SUPPLIES, LTD

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GENERAL SHOE SUPPLIES, LTD in 119208 NORTH STREET, STRATFORD, WI 54484 (NAICS 316998). OSHA activity number 344919659.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Shoe Supplies, LTD for free Get an email when a new federal OSHA severe-injury report for General Shoe Supplies, LTD is published. One employer, no account, unsubscribe in one click.
Site address
119208 NORTH STREET
City
STRATFORD
State
WI
ZIP
54484
Mailing
P.O. BOX 107, STRATFORD, WI 54484
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
316998
Employees
7
Ownership type
Private (A)

9 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 9 instances 6 exposed
Issued
Feb 5, 2021
Abate by
Mar 29, 2021
Penalty
Initial $4,096 · Current $2,867 Reduced
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:  The energy control procedures utilized for de-energizing the mechanical power presses (Press #2, 3, 4, 5, 6, 8,9, 10, 13) did not include specific procedural steps to ensure the flywheel came to a complete stop, press slide positioned at bottom dead center of its stroke, air pressure was discharged and turned off and locked, and the spring pressure was neutralized.
Recent events (2)
  • · I (S) $2867.2
  • · Z (S) $4096

1910.217 C05 I

Serious Gravity 10 1 instance 6 exposed
Issued
Feb 5, 2021
Abate by
Mar 8, 2021
Penalty
Initial $4,096 · Current $2,867 Reduced
29 CFR 1910.217(c)(5)(i): The employer shall use a control system and a brake monitor which comply with paragraphs (b)(13) and (14) of this section;  On or about August 31, 2020, the #13 Federal Press Company, 75-OBI did not have a control system and brake monitor installed when employee's were required to place hands in die exposing employees to crushing hazards.
Recent events (2)
  • · I (S) $2867.2
  • · Z (S) $4096

1910.217 D09 I

Serious Gravity 10 9 instances 2 exposed
Issued
Feb 5, 2021
Abate by
Mar 8, 2021
Penalty
Initial $4,096 · Current $2,867 Reduced
29 CFR 1910.217(d)(9)(i): The employer shall establish a die setting procedure that will insure compliance with paragraph (c) of this section.  During the week of August 24, 2020 and thereafter, die setting procedures were not developed and documented exposing employees to caught between hazards.
Recent events (2)
  • · I (S) $2867.2
  • · Z (S) $4096

1910.217 D09 IV

Serious Gravity 10 9 instances 2 exposed
Issued
Feb 5, 2021
Abate by
May 3, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.217(d)(9)(iv): The employer shall provide and enforce the use of safety blocks for use whenever dies are being adjusted or repaired in the press.  During the week of August 24, 2020 and thereafter,  safety blocks were not utilized when making adjustments of the dies in the press exposing employees to struck by hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.217 E01 I A

Serious Gravity 10 9 instances 6 exposed
Issued
Feb 5, 2021
Abate by
May 3, 2021
Penalty
Initial $4,096 · Current $2,867 Reduced
29 CFR 1910.217(e)(1)(i)(A): Conduct periodic and regular inspections of each power press to ensure that all of its parts, auxiliary equipment, and safeguards, including the clutch/brake mechanism, antirepeat feature, and single-stroke mechanism, are in a safe operating condition and adjustment;  The employer did not conduct a thorough periodic inspection of each power press to determine the condition of all its parts, auxiliary equipment, clutch/brake mechanism, antirepeat feature, and single-stroke mechanism exposing employees to struck by hazards.
Recent events (2)
  • · I (S) $2867.2
  • · Z (S) $4096

1910.217 E03

Serious Gravity 10 11 instances 6 exposed
Issued
Feb 5, 2021
Abate by
Mar 29, 2021
Penalty
Initial $4,096 · Current $2,867 Reduced
29 CFR 1910.217(e)(3): Training of maintenance personnel. It shall be the responsibility of the employer to insure the original and continuing competence of personnel caring for, inspecting, and maintaining power presses.  The employer did not train the maintenance personnel and those inspecting to ensure competency to care for, inspect, and maintain the power presses working properly.
Recent events (2)
  • · I (S) $2867.2
  • · Z (S) $4096

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 5, 2021
Abate by
Mar 8, 2021
Penalty
Initial $2,341 · Current $1,639 Reduced
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.  By the V & O Mechanical Power Press #9, a single metallic outlet box with knockouts was hanging by a type of tape not being used in accordance with the listing and labeling which required the box to be surface mounted exposing employees to electrical shock hazards.
Recent events (2)
  • · I (S) $1638.7
  • · Z (S) $2341

1910.303 G01

Serious Gravity 5 2 instances 6 exposed
Issued
Feb 5, 2021
Abate by
Mar 8, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.  The electrical disconnect for Press #8 and Press #9 was blocked with a radio and speaker system limiting the immediate access.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 C06 II

Other-than-serious 2 instances 2 exposed
Issued
Feb 5, 2021
Abate by
Mar 8, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.  The employer did not indicate which machine or equipment in which the energy control procedure was utilized for the periodic inspections conducted on October 22, 2019 and October 20, 2020.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344919659.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.