OSHA Inspection: INTEGRA-CAST, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of INTEGRA-CAST, INC. in 265 NEWINGTON AVENUE, NEW BRITAIN, CT 06051 (NAICS 331524). OSHA activity number 344926563.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Integra-Cast, INC. — free Get an email when a new federal OSHA severe-injury report for Integra-Cast, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
INTEGRA-CAST, INC.
Site address
265 NEWINGTON AVENUE
City
NEW BRITAIN
State
CT
ZIP
06051
Mailing
265 NEWINGTON AVENUE, NEW BRITAIN, CT 06051
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331524
Employees
72
Ownership type
A

8 citations on file for this inspection.

1910.36 B01

Serious Gravity 1 1 instance 8 exposed
Issued
Feb 2, 2021
Abate by
Jun 30, 2021
Penalty
Initial $4,096 · Current $2,048 Reduced
29 CFR  1910.36(b)(1):  At least two exits routes were not available to permit prompt evacuation of employees during an emergency:  Foundry:  On, or about, September 11, 2020, an adequate number of exits was not provided from the Foundry area.  Due to size of the room and type of operation, at least two exits were required.
Recent events (3)
  • — P (S) $2048
  • — I (S) $2048
  • — Z (S) $4096

1910.36 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 2, 2021
Abate by
Jun 30, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.36(e)(1):  A side-hinged door was not used to connect any room to an exit route:  Shell Room:  On, or about, September 11, 2020, a side-hinged exit door was not provided at either entrance to the Shell Room.  One end of the room was accessed through a sliding door and the other end was accessed through an overhead door.
Recent events (3)
  • — P (S) $0
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 5 3 instances 20 exposed
Issued
Feb 2, 2021
Abate by
Jun 15, 2021
Penalty
Initial $5,461 · Current $2,731 Reduced
29 CFR  1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  Plant:  On, or about, September 11, 2020, employees who operated forktrucks had not been provided with training.
Recent events (3)
  • — P (S) $2730.5
  • — I (S) $2730.5
  • — Z (S) $5461

1910.303 G01 II

Serious Gravity 1 1 instance 6 exposed
Issued
Feb 2, 2021
Penalty
Initial $3,481 · Current $1,741 Reduced
29 CFR  1910.303(g)(1)(ii):Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded:  Foundry:  On, or about, September 11, 2020, the area in front of the furnace controls was used for storage.
Recent events (2)
  • — I (S) $1740.5
  • — Z (S) $3481

1910.305 G01 IV A

Serious Gravity 5 6 instances 2 exposed
Issued
Feb 2, 2021
Penalty
Initial $4,642 · Current $2,321 Reduced
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  Shell Room:  On, or about, September 11, 2020, flexible cords were used in lieu of permanent wiring to energize fans used to dry parts along the conveyor system.
Recent events (2)
  • — I (S) $2321
  • — Z (S) $4642

1910.303 B02

Other-than-serious 1 instance 2 exposed
Issued
Feb 2, 2021
Abate by
Mar 22, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  FPI:  On, or about, October 22, 2021, Romex (Type NM) cable was used to energize fluorescent light fixtures mounted over a tank containing penetrant.  The cable was not supported and was energized through a male plug attachment.  Abatement Note:  The use of Nonmetallic Sheathed Cable (Types NM, NMC and NMS) is required to be in compliance with relevant portions of the National Electric Code, such as Article 334.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B07 I

Other-than-serious 2 instances 6 exposed
Issued
Feb 2, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(7)(i):  Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment:  Foundry:  On, or about, September 11, 2020, two knockouts were left open in the raceway under the enclosure for furnace controls.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 2 exposed
Issued
Feb 2, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(2)(i):  Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  Shell Room:  On, or about, September 11, 2020, a combination switch/receptacle outlet was not provided with a face plate.  The receptacle was used to energize a fan.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0