NEW BRITAIN, CT —
OSHA Inspection: INTEGRA-CAST, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of INTEGRA-CAST, INC. in 265 NEWINGTON AVENUE, NEW BRITAIN, CT 06051 (NAICS 331524). OSHA activity number 344926563.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTEGRA-CAST, INC.
- Site address
- 265 NEWINGTON AVENUE
- City
- NEW BRITAIN
- State
- CT
- ZIP
- 06051
- Mailing
- 265 NEWINGTON AVENUE, NEW BRITAIN, CT 06051
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331524
- Employees
- 72
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.36 B01
- Issued
- Feb 2, 2021
- Abate by
- Jun 30, 2021
- Penalty
- Initial $4,096 · Current $2,048 Reduced
General-duty citation text
29 CFR 1910.36(b)(1): At least two exits routes were not available to permit prompt evacuation of employees during an emergency: Foundry: On, or about, September 11, 2020, an adequate number of exits was not provided from the Foundry area. Due to size of the room and type of operation, at least two exits were required.
Recent events (3)
- — P (S) $2048
- — I (S) $2048
- — Z (S) $4096
1910.36 E01
- Issued
- Feb 2, 2021
- Abate by
- Jun 30, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(e)(1): A side-hinged door was not used to connect any room to an exit route: Shell Room: On, or about, September 11, 2020, a side-hinged exit door was not provided at either entrance to the Shell Room. One end of the room was accessed through a sliding door and the other end was accessed through an overhead door.
Recent events (3)
- — P (S) $0
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Feb 2, 2021
- Abate by
- Jun 15, 2021
- Penalty
- Initial $5,461 · Current $2,731 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): Plant: On, or about, September 11, 2020, employees who operated forktrucks had not been provided with training.
Recent events (3)
- — P (S) $2730.5
- — I (S) $2730.5
- — Z (S) $5461
1910.303 G01 II
- Issued
- Feb 2, 2021
- Penalty
- Initial $3,481 · Current $1,741 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii):Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded: Foundry: On, or about, September 11, 2020, the area in front of the furnace controls was used for storage.
Recent events (2)
- — I (S) $1740.5
- — Z (S) $3481
1910.305 G01 IV A
- Issued
- Feb 2, 2021
- Penalty
- Initial $4,642 · Current $2,321 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Shell Room: On, or about, September 11, 2020, flexible cords were used in lieu of permanent wiring to energize fans used to dry parts along the conveyor system.
Recent events (2)
- — I (S) $2321
- — Z (S) $4642
1910.303 B02
- Issued
- Feb 2, 2021
- Abate by
- Mar 22, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: FPI: On, or about, October 22, 2021, Romex (Type NM) cable was used to energize fluorescent light fixtures mounted over a tank containing penetrant. The cable was not supported and was energized through a male plug attachment. Abatement Note: The use of Nonmetallic Sheathed Cable (Types NM, NMC and NMS) is required to be in compliance with relevant portions of the National Electric Code, such as Article 334.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B07 I
- Issued
- Feb 2, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment: Foundry: On, or about, September 11, 2020, two knockouts were left open in the raceway under the enclosure for furnace controls.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02 I
- Issued
- Feb 2, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: Shell Room: On, or about, September 11, 2020, a combination switch/receptacle outlet was not provided with a face plate. The receptacle was used to energize a fan.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Integra-Cast, INC.
View Integra-Cast, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331524)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344926563.