SIOUX FALLS, SD ·
OSHA Inspection: SECURE ENTERPRISE ASSET MANAGEMENT, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SECURE ENTERPRISE ASSET MANAGEMENT, INC. in 3101 NORTH 1ST AVENUE, SIOUX FALLS, SD 57104 (NAICS 423930). OSHA activity number 344928668.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SECURE ENTERPRISE ASSET MANAGEMENT, INC.
- Site address
- 3101 NORTH 1ST AVENUE
- City
- SIOUX FALLS
- State
- SD
- ZIP
- 57104
- Mailing
- 3101 NORTH 1ST AVENUE, SIOUX FALLS, SD 57104
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 11
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C04 II
- Issued
- Jan 27, 2021
- Abate by
- Feb 23, 2021
- Penalty
- Initial $3,901 · Current $3,901
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items of this section: (a)Secure Enterprise Asset Management, Inc. at 3101 North 1st Avenue, Sioux Falls, SD 57104: On or about and at times prior to September 11, 2020, the employer did not establish clear and specific procedures to outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy regarding baling machinery. The energy control procedures related to the Marathon Heavy Duty Vertical Balers were not clear and specifically outlined to address lock-out/tag-out procedures de-energization involving breakers in the main electrical panel. The company had recently moved into a new facility and did not update specific procedures involving the vertical balers. This condition exposed the employees to the hazards of improper lockout procedures. Abatement Note: The procedures shall include but are not limited to the following: (1) A specific statement of the intended use of the procedures; (2) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; (3) Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and (4) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (O) $3901
- · Z (S) $3901
1910.212 A01
- Issued
- Jan 27, 2021
- Abate by
- Feb 23, 2021
- Penalty
- Initial $5,461 · Current $5,461
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a)Secure Enterprise Asset Management, Inc. at 3101 North 1st Avenue, Sioux Falls, SD 57104: On or about and at times prior to September 11, 2020, the employer did not ensure employees were protected from amputation hazards associated with exposed pinch-points regarding a vertical baler. Employees were utilizing a large magnet to bypass the magnetic feed gate interlock on the Marathon Heavy Duty Vertical Baler to create plastic bales. In order to increase the weight of the plastic bales, the magnet was used to allow the feed gate to remain open and the platen to cycle while an employee added additional plastic computer components within the baler. This condition exposed employees to amputation hazards related to the point of operation or the platen and bypassing the interlocked feed gate. (b)Secure Enterprise Asset Management, Inc. at 3101 North 1st Avenue, Sioux Falls, SD 57104: On or about and at times prior to September 11, 2020, the employer did not ensure employees were protected from amputation hazards associated with exposed pinch-points regarding a vertical baler. The feed gate on the Marathon Heavy Duty Vertical Baler baler designated as the metal baler, had openings in the fabricated metal guard of approximately two to three inches. This condition exposed employees to amputation hazards related to the point of operation or the platen while creating metal bales. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (O) $5461
- · Z (S) $5461
1910.146 C02
- Issued
- Jan 27, 2021
- Abate by
- Feb 23, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: (a)Secure Enterprise Asset Management, Inc. at 3101 North 1st Avenue, Sioux Falls, SD 57104: On or about and at times prior to September 11, 2020, the employer did not inform exposed employees by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit-required spaces which includes, but is not limited to, the Marathon Heavy-Duty Vertical balers. This condition exposed employees to crushing hazards. Abatement Note: A sign reading "DANGER-PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER" or using other similar language would satisfy the requirement for a sign. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 423930)
More inspections in SD
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344928668.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.