Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: NC EMPLOYMENT GROUP, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of NC EMPLOYMENT GROUP, INC. in 21504 PALATKA DRIVE, VENICE, FL 34293 (NAICS 236115). OSHA activity number 344931159.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NC Employment Group, INC. for free Get an email when a new federal OSHA severe-injury report for NC Employment Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
21504 PALATKA DRIVE
City
VENICE
State
FL
ZIP
34293
Mailing
5800 LAKEWOOD RANCH BLVD, SARASOTA, FL 34240
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
9
Ownership type
Private (A)

1 citation on file for this inspection.

1926.706 B

Deleted Serious Gravity 10 1 instance 9 exposed
Issued
Nov 9, 2020
Abate by
Dec 7, 2020
Penalty
Initial $12,145 · Current $0 Reduced
29 CFR 1926.706(b): Masonry walls over eight feet in height were not adequately braced to prevent overturning and to prevent collapse until permanent supporting elements of the structure were in place:  a.  On or about June 27, 2020 and at times prior, at the residential construction site in Venice, Florida. The employer did not assure that the 88' L x 8" W x 10' H wall on the right elevation side of the house, was adequately braced to prevent shifting and/or collapsing. No bracing method was used on either side of the wall after it's completion and removal of scaffold, exposing sub-contracted employees to struck and crushed-by hazards.