Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PINCUS ELEVATOR COMPANY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PINCUS ELEVATOR COMPANY, INC. in 2024 N. 2ND ST, PHILADELPHIA, PA 19122 (NAICS 238290). OSHA activity number 344937685.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pincus Elevator Company, INC. — free Get an email when a new federal OSHA severe-injury report for Pincus Elevator Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2024 N. 2ND ST
City
PHILADELPHIA
State
PA
ZIP
19122
Mailing
901 SOUTH BOLMAR STREET SUITE Q, WEST CHESTER, PA 19382
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238290
Employees
8
Ownership type
A

2 citations on file for this inspection.

1926.501 A02

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Feb 5, 2021
Abate by
Mar 4, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.501(a)(2): The employer did not determine if the walking/working surfaces on which its employees were to work had the strength and structural integrity to support employees safely:  a)  Jobsite - 2024 North 2nd Street, Philadelphia, PA - The employer did not make a determination that the elevator car where employees had to work had the strength and structural integrity to support the employees safely thus exposing the employee to fall, struck-by and caught-in-between hazards. An employee working atop an elevator car suffered severe injuries after the elevator car he was dismantling broke free of its rigging fell 100 feet. Observed on or about 06 AUG 2020.
Recent events (2)
  • — I (O) $4096
  • — Z (S) $4096

1926.502 A02

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Feb 5, 2021
Abate by
Mar 4, 2021
Penalty
Initial $4,505 · Current $4,505
29 CFR  1926.502(a)(2):The employer did not provide and install all fall protection systems required by this subpart for employee(s) and did not comply with all other pertinent requirements of this subpart before employee(s) began the work that necessitates the fall protection:  a) Jobsite - 2024 North 2nd Street, Philadelphia, PA - The employer did not ensure that all employees working on top of an elevator car were protected against falls of approximately one hundred (100) feet above grade by means of personal fall arrest systems, independent lifelines, guardrails or similar systems thus exposing employees to fall hazards. An employee working atop an elevator car suffered severe injuries after the elevator car he was dismantling fell 100 feet.  Observed on or about 06 AUG 2020.
Recent events (2)
  • — I (O) $4505
  • — Z (S) $4505

View Pincus Elevator Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344937685.