Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: C.H. TOOL, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of C.H. TOOL, INC in 7339 KINGSLEY ST, HOUSTON, TX 77087 (NAICS 332999). OSHA activity number 344953419.

Watch C.H. Tool, INC — free Get an email when a new federal OSHA severe-injury report for C.H. Tool, INC is published. One employer, no account, unsubscribe in one click.
Establishment
C.H. TOOL, INC
Site address
7339 KINGSLEY ST
City
HOUSTON
State
TX
ZIP
77087
Mailing
7339 KINGSLEY ST, HOUSTON, TX 77087
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
6
Ownership type
A

5 citations on file for this inspection.

1910.215 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $2048.00 Reduced
29 CFR  1910.215(b)(1): Cup wheel(s) of grinder(s) were not protected by guards:   a) At the shop department, the point of operation of a Cincinnati V thread grinder, serial #31512T5W-43, was not guarded, exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $2048
  • — Z (S) $4096

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2341.00 · Current $2048.00 Reduced
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a)  At the shop department, a relocatable power tap was permanently secured to a Cincinnati grinder, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $2048
  • — Z (S) $2341

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2926.00 · Current $0.00 Reduced
29 CFR  1910.305(b)(1)(ii):  Unused openings in boxes, cabinets, or fittings were not effectively closed:  a)  At the west side of the building, an electrical panel had missing breaker blanks, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2926

1910.334 A02 II

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $0.00 Reduced
29 CFR  1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:     a)  At the shop department, employees used a damaged electrical cord and it was not removed from service, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4096

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2926.00 · Current $1448.00 Reduced
29 CFR  1904.39(a)(2):The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye:    a)  On or about September 8, 2020, the employer did not report to OSHA the hospitalization of an employee within 24-hours of the work-related incident causing the hospitalization.
Recent events (2)
  • — I (O) $1448
  • — Z (O) $2926

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344953419.