WESTMONT, IL —
OSHA Inspection: MOKENA CARPENTRY SOLUTIONS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MOKENA CARPENTRY SOLUTIONS INC. in 416 N. CASS AVE, WESTMONT, IL 60559 (NAICS 238130). OSHA activity number 344954581.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOKENA CARPENTRY SOLUTIONS INC.
- Site address
- 416 N. CASS AVE
- City
- WESTMONT
- State
- IL
- ZIP
- 60559
- Mailing
- 20033 LAKEVIEW WAY, MOKENA, IL 60448
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.453 B02 V
- Issued
- Oct 20, 2020
- Abate by
- Nov 3, 2020
- Penalty
- Initial $2,892 · Current $1,755 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:Note: As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated 1926.502(e). On or about October 2, 2020, employees were performing framing operations outside a residential property using a JLG 450 AJ aerial lift and were exposed to fall hazards of 16 feet, 6 inches feet when the employer failed to ensure that fall protection was utilized. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $1755
- — Z (S) $2892
1926.454 A01
- Issued
- Oct 20, 2020
- Abate by
- Nov 3, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a)(1): The employer failed to have each employee who performs work while on a scaffold trained regarding the nature of any electrical hazards, fall hazards and falling object hazards in the work area. On or about October 2, 2020, the employer did not ensure that employees were trained to recognize and minimize hazards associated with falls while operating aerial lifts. Two employees were performing framing operations outside a residential property using a JLG 450 AJ aerial boom lift at a residential property and were exposed to fall hazards of 11 feet, 6 inches when they failed to utilize fall protection. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Mokena Carpentry Solutions INC.
View Mokena Carpentry Solutions INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344954581.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.