JONESBURG, MO —
OSHA Inspection: CERTAINTEED ROOFING
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CERTAINTEED ROOFING in 100 CERTAINTEED DRIVE, JONESBURG, MO 63351 (NAICS 324122). OSHA activity number 344960612.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CERTAINTEED ROOFING
- Site address
- 100 CERTAINTEED DRIVE
- City
- JONESBURG
- State
- MO
- ZIP
- 63351
- Mailing
- 100 CERTAINTEED DRIVE, JONESBURG, MO 63351
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 324122
- Employees
- 126
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C06 I
- Issued
- Mar 26, 2021
- Abate by
- Apr 21, 2021
- Penalty
- Initial $13,653 · Current $13,653
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. On or about 10/01/2020, the employer had not perform the required annual inspection of the energy control procedures. On 09/27/2020, a maintenance worker suffered burns while changing a pressure relief valve on the number 1 hot oil system heater.
Recent events (1)
- — Z (S) $13653
1910.147 C06 II
- Issued
- Mar 26, 2021
- Abate by
- Apr 21, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii):The employer did not certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. On or about 10/01/2020, the employer did not certify that the annual inspection have been performed.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 324122)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344960612.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.