ASHLAND, MA —
OSHA Inspection: TEKNI-PLEX FLEXIBLES, LLC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TEKNI-PLEX FLEXIBLES, LLC. in 150 HOMER AVE, ASHLAND, MA 01721 (NAICS 322220). OSHA activity number 344961800.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TEKNI-PLEX FLEXIBLES, LLC.
- Site address
- 150 HOMER AVE
- City
- ASHLAND
- State
- MA
- ZIP
- 01721
- Mailing
- 150 HOMER AVE, ASHLAND, MA 01721
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322220
- Employees
- 22
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 D02
- Issued
- Dec 14, 2020
- Abate by
- Jan 4, 2021
- Penalty
- Initial $9,639 · Current $5,300 Reduced
General-duty citation text
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment Location: 150 Homer Ave, Ashland, MA Printing press#3-Marc Andy printing and rotary dye cutting machine Serial number: 6305 Model number: 43048610Y-27 On or about September 18, 2020, a Marc Andy rotary printing and dye cutting machine (press# 3, serial # 6305, model # 43048610Y-27) was not shut down or deenergized using the procedures established for the machine.
Recent events (2)
- — I (S) $5300
- — Z (S) $9639
1910.147 C04 II
- Issued
- Dec 14, 2020
- Abate by
- Feb 2, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about September 18, 2020, LOTO written procedures did not clearly and specifically outline the techniques to be utilized for the control of hazardous energy.