Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J. D. WEBER CONSTRUCTION CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J. D. WEBER CONSTRUCTION CO. in 18200 U.S. HWY 441, MOUNT DORA, FL 32757 (NAICS 237110). OSHA activity number 344962824.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J. D. Weber Construction CO. — free Get an email when a new federal OSHA severe-injury report for J. D. Weber Construction CO. is published. One employer, no account, unsubscribe in one click.
Site address
18200 U.S. HWY 441
City
MOUNT DORA
State
FL
ZIP
32757
Mailing
PO BOX 730386, ORMOND BEACH, FL 32174
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
51
Ownership type
A

5 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 31, 2020
Abate by
Jan 28, 2021
Penalty
Initial $9,446 · Current $9,446
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  a.  On or about Oct 7, 2020, at the jobsite, exposed employees working in a trench that measured 8 feet deep, in type C soil, and without cave-in protection were not trained to recognize the hazards associated with working in and around a trench.
Recent events (1)
  • — Z (S) $9446

1926.651 C02

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 31, 2020
Penalty
Initial $8,096 · Current $8,096
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  a.	On or about Oct 7, 2020, at the jobsite, exposed employees working in a trench that measured 8 feet deep, in type C soil, and without cave-in protection were not provided a safe means of egress.
Recent events (1)
  • — Z (S) $8096

1926.651 K02

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 31, 2020
Penalty
Initial $9,446 · Current $9,446
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety:  a.  On or about Oct 7, 2020, at the jobsite, employees were directed to work in a trench after two competent persons noticed hazards including cracks and fissures along the trench walls, no safe means of egress, no cave-in protection, and the spoil pile was placed directly at the edge of the trench wall. The trench measured 8 feet deep and was in previously disturbed Type C soil.
Recent events (1)
  • — Z (S) $9446

1926.652 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 31, 2020
Penalty
Initial $9,446 · Current $9,446
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).  a.  On or about Oct 7, 2020, at the jobsite, cave-in protection was not provided to employees working in a trench that measured 8 feet deep, in type C soil.
Recent events (1)
  • — Z (S) $9446

1904.40 A

Other-than-serious 1 instance 4 exposed
Issued
Dec 31, 2020
Abate by
Jan 7, 2021
Penalty
Initial $1,350 · Current $1,350
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours:  a. On or about Oct 07, 2020, at the jobsite, the employer failed to provide the OSHA 300 and 300A's for the years 2017-2020.
Recent events (1)
  • — Z (O) $1350

View J. D. Weber Construction CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344962824.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.