MELBOURNE, FL —
OSHA Inspection: HIGH TECH COMPOSITES II, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of HIGH TECH COMPOSITES II, LLC in 2910 DUSA DRIVE, MELBOURNE, FL 32934 (NAICS 336612). OSHA activity number 344964200.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HIGH TECH COMPOSITES II, LLC
- Site address
- 2910 DUSA DRIVE
- City
- MELBOURNE
- State
- FL
- ZIP
- 32934
- Mailing
- 2910 DUSA DRIVE, MELBOURNE, FL 32934
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336612
- Employees
- 20
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.134 C
- Issued
- Dec 31, 2020
- Abate by
- Jan 28, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: a) High Tech Composites II - A written respiratory protection program was not developed and employees were required to wear 3M half-face respirators, on or about October 21, 2020.
Recent events (1)
- — Z (O) $0
1910.134 F01
- Issued
- Dec 31, 2020
- Abate by
- Jan 28, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer shall ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph: a) High Tech Composites II - Fit tests were not conducted and employees were required to wear 3M half-face respirators, on or about October 21, 2020.
Recent events (1)
- — Z (O) $0
1910.134 G01 I A
- Issued
- Dec 31, 2020
- Abate by
- Jan 28, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: a) High Tech Composites II - An employee, wearing a 3M half-face respirator, had a beard, on or about October 21, 2020.
Recent events (1)
- — Z (O) $0
More inspections at High Tech Composites II, LLC
View High Tech Composites II, LLC's full OSHA safety record →
More inspections in this industry (NAICS 336612)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344964200.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.