OSHA Inspection: MAHONEY DESIGN & BUILD

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of MAHONEY DESIGN & BUILD in 222 TULIP STREET, LIVERPOOL, NY 13089 (NAICS 238190). OSHA activity number 344964507.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mahoney Design & Build — free Get an email when a new federal OSHA severe-injury report for Mahoney Design & Build is published. One employer, no account, unsubscribe in one click.
Site address
222 TULIP STREET
City
LIVERPOOL
State
NY
ZIP
13089
Mailing
4 TECHNOLOGY BLVD, CANASTOTA, NY 13032
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
15
Ownership type
A

5 citations on file for this inspection.

1926.56 A

Deleted Serious Gravity 5 1 instance 7 exposed
Issued
Oct 28, 2020
Abate by
Nov 9, 2020
Penalty
Initial $3,084 · Current $0 Reduced
29 CFR 1926.56(a): While work was in progress, construction areas, ramps, runways, corridors, offices, shops or storage areas were not lighted to the minimum illumination intensities as listed in Table D-3 of 29 CFR 1926.56:  b)  At the jobsite, inside building #2, on the first floor, on or about 6/30/20:  Workers were transiting through and working inside areas where no lighting was provided and readings were measured between .01 and .06 lumens and was occasionally too dark to read the device.
Recent events (3)
  • — J (S) $0
  • — C (S) $3084
  • — Z (S) $3084

1926.501 B01

Deleted Serious Gravity 10 1 instance 7 exposed
Issued
Oct 28, 2020
Abate by
Nov 3, 2020
Penalty
Initial $5,398 · Current $0 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a)  At the jobsite, on the second floor of building #2, on or about 6/30/20:  Employees worked in close proximity to an unguarded stairwell opening, and were not provided other fall protection, exposing workers to falls of 10 feet to the lower level.
Recent events (3)
  • — J (S) $0
  • — C (S) $5398
  • — Z (S) $5398

1926.601 B04 I

Deleted Serious Gravity 5 1 instance 7 exposed
Issued
Oct 28, 2020
Abate by
Nov 9, 2020
Penalty
Initial $3,856 · Current $0 Reduced
29 CFR 1926.601(b)(4)(i): The employer used motor vehicle equipment with an obstructed view to the rear, and did not have a reverse signal alarm audible above the surrounding noise level.  a)  At the jobsite, in the driveway areas, on or about 6/30/20:  Employees operated trucks without operating backup alarms.
Recent events (3)
  • — J (S) $0
  • — C (S) $3856
  • — Z (S) $3856

1926.1052 A03

Serious Gravity 10 1 instance 7 exposed
Issued
Oct 28, 2020
Abate by
Nov 9, 2020
Penalty
Initial $5,398 · Current $3,000 Reduced
29 CFR 1926.1052(a)(3): Riser height and/or tread depth was not uniform within each flight of stairs:   a)  At the jobsite, inside building #2, on or about 6/30/20:  Workers were using a temporary stairwell to access and egress the second floor of the building where the treads of that stairwell were inconsistent in both rise and run on each step.
Recent events (3)
  • — J (S) $3000
  • — C (S) $5398
  • — Z (S) $5398

1926.1052 C01 I

Serious Gravity 10 1 instance 7 exposed
Issued
Oct 28, 2020
Abate by
Nov 9, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS)Note:  29 CFR 1926.1052(c)(7) applies when the top edge of a stairrail system also serves as a handrail.  a)  At the jobsite, inside building #2, on or about 6/30/20:  Workers were using a temporary stairwell to access and egress the second floor of the building where the treads of that stairwell were inconsistent in both rise and run on each step and did not have a handrail.