Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: F & G CARPENTRY INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of F & G CARPENTRY INC. in 701 SW 17TH STREET, MOORE, OK 73160 (NAICS 238130). OSHA activity number 344968227.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch F & G Carpentry INC. — free Get an email when a new federal OSHA severe-injury report for F & G Carpentry INC. is published. One employer, no account, unsubscribe in one click.
Site address
701 SW 17TH STREET
City
MOORE
State
OK
ZIP
73160
Mailing
1413 E KENOSHA ST., BROKEN ARROW, OK 74012
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
12
Ownership type
A

10 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 16, 2021
Penalty
Initial $2,340 · Current $2,340
29 CFR  1926.100(a):  Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns.  On or about October 7, 2020, at an exterior side of building A, an employee in an extensible boom lift basket did not wear a hard hat  when there was possible danger of impacting building surfaces.  The employee was exposed to head injuries when working in an aerial lift basket under building surfaces.
Recent events (1)
  • — Z (S) $2340

1926.501 C01

Serious Gravity 1 3 instances 3 exposed
Issued
Mar 16, 2021
Abate by
Mar 26, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.501(c)(1):  When employees were exposed to falling objects, the employer did not have each employee wear a hard hat and did not erect toeboards, screens, canopy structures or barricades to prevent objects from falling from higher levels.   On or about October 7, 2020, at building A, the employer did not erect toeboards, screens, canopy structures or barricades to prevent objects from falling from higher levels at areas including but not limited to the following:   a. 4th floor overhead of stair case for 3rd floor b. Building A, 4th floor, wall openings at the south side c. Building A, southside stair landings  Employees were exposed to struck-by hazards from objects falling overhead.
Recent events (1)
  • — Z (S) $0

1926.405 G02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 16, 2021
Abate by
Mar 26, 2021
Penalty
Initial $2,340 · Current $2,340
29 CFR  1926.405(g)(2)(ii):  Type SJ, SJO, SJT, SJTO, S, SO, ST, or STO flexible cords were used without being durably marked on the surface with the type designation, size, and number of conductors.  On or about October 7, 2020, at the 4th Floor Building A, an unmarked electrical extension cord powered other electrical extension cords to power a circular saw.  Employees were exposed to electrical hazards when using unmarked electrical extension cords.
Recent events (1)
  • — Z (S) $2340

1926.405 G02 IV

Serious Gravity 1 2 instances 1 exposed
Issued
Mar 16, 2021
Abate by
Mar 26, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.405(g)(2)(iv):  Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws.  a.  On or about October 7, 2020, at the 4th floor Building A, an electrical extension cord that lacked strain relief, powered an electrical extension cord that powered a circular saw and exposed employees to electrical hazards.  b.  On or about October 7, 2020, at the 1st floor Building A, temporary power receptacle, an electrical extension cord lacked strain relief and powered other electrical extension cords and exposed employees to electrical hazards.
Recent events (1)
  • — Z (S) $0

1926.416 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 16, 2021
Abate by
Mar 26, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.416(e)(1):  Worn or frayed electric cords or cables were used.  On or about October 7, 2020, at the 4th Floor Building A, an electrical extension cord was frayed and the covered conductors extended beyond the outer jacket of the cord.  Employees were exposed to electrical hazards when using frayed electrical cords.
Recent events (1)
  • — Z (S) $0

1926.416 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 16, 2021
Penalty
Initial $2,340 · Current $2,340
29 CFR  1926.416(b)(2):  Working spaces, walkways, and similar locations were not kept clear of cords which created a hazard to employees.  On or about October 7, 2020, at a stairwell of Building A, the employer allowed for electrical extension cords to be laid across the stairs, exposing employees to tripping hazards.
Recent events (1)
  • — Z (S) $2340

1926.453 B02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 16, 2021
Abate by
Mar 26, 2021
Penalty
Initial $3,121 · Current $3,121
29 CFR  1926.453(b)(2)(v):  A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift.    On or about October 7, 2020, at an exterior side of building A, an employee in an extensible boom lift basket did not have a lanyard attached to the boom or basket and was not restrained from being thrown from the extensible boom lift basket.  The employee was exposed to falls greater than 6 feet to a lower level.
Recent events (1)
  • — Z (S) $3121

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 16, 2021
Abate by
Mar 26, 2021
Penalty
Initial $3,901 · Current $3,901
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b).    On or about October 7, 2020, Building A, the employer did not ensure that an employee, working at the unprotected edge of a balcony on the fourth floor,  was protected from falling by the use of guardrail systems, safety net systems, or personal protective equipment.   The employee was exposed to a fall greater than six feet to a lower level.
Recent events (1)
  • — Z (S) $3901

1926.502 B02

Serious Gravity 5 2 instances 3 exposed
Issued
Mar 16, 2021
Abate by
Mar 26, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.502(b)(2):  Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high.  a.  On or about October 7, 2020, building A, southside of the 4th floor, a wall opening lacked a midrail.  An employee who worked near the wall opening was exposed to falls greater than 6 feet to a lower level.  b.  On or about October 7, 2020, building A southside stairwell, stair landing between 2nd and 3rd floor, a midrail was not installed between the top edge of the wall and the floor, at a height of at least 21 inches along the length of the wall opening.  Employees were exposed to falls greater than 6 feet to a lower level at the stair landing.
Recent events (1)
  • — Z (S) $0

1926.502 B06

Other-than-serious 2 instances 3 exposed
Issued
Mar 16, 2021
Abate by
Mar 26, 2021
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(6):  Guardrail systems were not surfaced as to prevent injury to an employee from punctures or lacerations, and to prevent snagging of the clothing.   On or about October 7, 2020, at building A, guardrails had protruding nails and/or screws and were not surfaced to prevent injuries to employees from punctures or lacerations and to prevent snagging of the clothing at locations including, but not limited to the following:   a. Building A, 4th floor interior wall opening guardrail adjacent to stair rail, b. Building A, 4th floor, guardrail at a breezeway wall opening.
Recent events (1)
  • — Z (O) $0

View F & G Carpentry INC.'s full OSHA safety record →