OSHA Inspection: PEDRO ANTONIO ESPINOSA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PEDRO ANTONIO ESPINOSA in 2612 TUSCARAIA, RED OAK, TX 75154 (NAICS 238350). OSHA activity number 344973193.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pedro Antonio Espinosa for free Get an email when a new federal OSHA severe-injury report for Pedro Antonio Espinosa is published. One employer, no account, unsubscribe in one click.
Site address
2612 TUSCARAIA
City
RED OAK
State
TX
ZIP
75154
Mailing
517 NE 18TH ST., GRAND PRAIRIE, TX 75050
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
3
Ownership type
Private (A)

3 citations on file for this inspection.

1926.451 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 22, 2020
Penalty
Initial $1,475 · Current $885 Reduced
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide.     On the east side of the construction site, employees engaged in cornice work on a residential home from a single pole scaffold, worked from a platform not 18 inches wide.  The employees were exposed to a fall hazard of approximately 11 feet to the ground below.
Recent events (2)
  • · I (S) $885
  • · Z (S) $1475

1926.451 G01 VII

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 22, 2020
Penalty
Initial $1,966 · Current $1,180 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.     On the east side of the construction site, employees working from a pole scaffold without a fall protection system while installing cornice material on the exterior of a residential home.  The employees were exposed to a fall hazards of approximately 11 feet to the ground below.
Recent events (2)
  • · I (S) $1179.6
  • · Z (S) $1966

1926.452 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.452(a)(4): Diagonal bracing in both directions were not installed across the entire outside face of all double- and single-pole scaffolds.   On the east side of the construction site, employees working from a pole scaffold without cross bracing installed was exposed to a fall hazard of approximately 11 feet to the ground below.