CHICAGO, IL —
OSHA Inspection: DAKKOTA INTEGRATED SYSTEMS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DAKKOTA INTEGRATED SYSTEMS, LLC in 12525 CARONDOLET, CHICAGO, IL 60633 (NAICS 336111). OSHA activity number 344975784.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAKKOTA INTEGRATED SYSTEMS, LLC
- Site address
- 12525 CARONDOLET
- City
- CHICAGO
- State
- IL
- ZIP
- 60633
- Mailing
- 12525 CARONDOLET, CHICAGO, IL 60633
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336111
- Employees
- 300
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Mar 9, 2021
- Abate by
- Mar 9, 2021
- Penalty
- Initial $13,653 · Current $6,830 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a) Production Warehouse - On or about September 12, 2020, an employee was exposed to machine hazards associated with moving parts and pinch-points during servicing of an auto torque machine RMOD 460, which resulted in an injury of the employees hand. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect the employee from servicing hazards.
Recent events (2)
- — I (O) $6830
- — Z (S) $13653
More inspections at Dakkota Integrated Systems, LLC
View Dakkota Integrated Systems, LLC's full OSHA safety record →
More inspections in this industry (NAICS 336111)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344975784.