OSHA Inspection: QUILTER'S RULE INTERNATIONAL, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of QUILTER'S RULE INTERNATIONAL, LLC in 817 MOHR AVENUE, WATERFORD, WI 53185 (NAICS 451130). OSHA activity number 344976691.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quilter'S Rule International, LLC — free Get an email when a new federal OSHA severe-injury report for Quilter'S Rule International, LLC is published. One employer, no account, unsubscribe in one click.
Site address
817 MOHR AVENUE
City
WATERFORD
State
WI
ZIP
53185
Mailing
817 MOHR AVENUE, WATERFORD, WI 53185
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
451130
Employees
7
Ownership type
A

6 citations on file for this inspection.

1910.178 Q01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 19, 2020
Abate by
Dec 9, 2020
Penalty
Initial $0 · Current $0
29 CFR  1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:  (a) On October 14, 2020, the Allis Chalmers forklift was not removed from service after the employer was made aware that the brakes were not operating properly. This exposed employees to a struck-by hazard.
Recent events (1)
  • — Z (S) $0

1910.219 F03

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 19, 2020
Abate by
Dec 9, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed:  (a) On October 14, 2020, employees operating or working around the mat roller cart were exposed to caught-in hazards and amputation injury from an unguarded chain and sprocket.
Recent events (1)
  • — Z (S) $0

1910.157 C01

Other-than-serious 1 instance 1 exposed
Issued
Nov 19, 2020
Abate by
Nov 25, 2020
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  (a) On or about October 14 , 2020, the fire extinguisher(s) at the laser cutting machine was not mounted to the wall or other suitable location.
Recent events (1)
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Nov 19, 2020
Abate by
Dec 9, 2020
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) On or About October 14, 2020, an outlet box, intended for fixed installation, was used on an extension cord to power a floor fan.
Recent events (1)
  • — Z (O) $0

1910.303 G01 I A

Other-than-serious 1 instance 1 exposed
Issued
Nov 19, 2020
Abate by
Dec 2, 2020
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:  (a) On or about October 14, 2020, the electrical panels in the shop area, on the west wall, were not kept clear (at least 3 feet in front of the panels) for ease of access.
Recent events (1)
  • — Z (O) $0

1910.305 G01 I

Other-than-serious 1 instance 1 exposed
Issued
Nov 19, 2020
Abate by
Dec 2, 2020
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(i): Flexible cords and cables were not approved for conditions of use and location:  (a) On or about October 14, 2020, a flexible electrical cord used to power the printing machine, was on the ground in the walkway. This exposed the power cable to damage.