Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELECTRO PAINTING & REFURBISHING, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ELECTRO PAINTING & REFURBISHING, INC. in 2277 ADMINISTRATION DR, MARYLAND HEIGHTS, MO 63043 (NAICS 332812). OSHA activity number 344978598.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Electro Painting & Refurbishing, INC. — free Get an email when a new federal OSHA severe-injury report for Electro Painting & Refurbishing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2277 ADMINISTRATION DR
City
MARYLAND HEIGHTS
State
MO
ZIP
63043
Mailing
2277 ADMINISTRATION DR., MARYLAND HEIGHTS, MO 63043
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
3
Ownership type
A

3 citations on file for this inspection.

1910.305 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 8, 2021
Penalty
Initial $2,736 · Current $1,915 Reduced
29 CFR  1910.305(b)(1)(i):Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter  were not effectively closed.  On or 10/16/2020, conductors entering an electrical box of the electrostatic spray painting apparatus were not protected from abrasion.
Recent events (2)
  • — I (S) $1915.2
  • — Z (S) $2736

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 8, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(1)(ii):Unused openings in cabinets, boxes, and fittings shall be effectively closed.  On or about 10/16/2020, on the east wall , of the electrostatic spray finishing area,  an electrical outlet box was not fully covered. The outlet box had two openings.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 E01

Other-than-serious 1 instance 3 exposed
Issued
Apr 8, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(1):The employer was not responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace.  a) On or about 10/16/2020, two portable fire extinguishers located on the north wall of the electrostatic spray finishing area and paint mixing area were not inspected.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344978598.