KINGFISHER, OK —
OSHA Inspection: ROWDY OILFIELD SERVICES LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ROWDY OILFIELD SERVICES LLC in CR 2770 & CR 810 DAN NO. 1H-17X, KINGFISHER, OK 73750 (NAICS 213112). OSHA activity number 344979315.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROWDY OILFIELD SERVICES LLC
- Site address
- CR 2770 & CR 810 DAN NO. 1H-17X
- City
- KINGFISHER
- State
- OK
- ZIP
- 73750
- Mailing
- PO BOX 284, ERICK, OK 73645
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 5
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.138 A
- Issued
- Mar 16, 2021
- Abate by
- Mar 26, 2021
- Penalty
- Initial $3,979 · Current $2,387 Reduced
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes. On or about October 13, 2020, at an oil and gas well pad, the employer did not require an employee to use fire resistant hand protection when working at a produced water tank where a contract welder used an oxygen acetylene torch. This exposed employees to fire hazards.
Recent events (2)
- — I (S) $2387.4
- — Z (S) $3979
1910.252 A02 IV
- Issued
- Mar 16, 2021
- Abate by
- Mar 26, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.252(a)(2)(iv): The individual responsible for authorizing cutting or welding operations did not designate precautions to be followed in granting authorization to proceed preferably in the form of a written permit. On or about October 13, 2020, at an oil and gas well pad, the employer did not designate precautions to be followed which include, but are not limited to air testing the tank interior for flammable atmospheres, prior to allowing a contract welder to use an oxygen acetylene torch on the exterior of a produced water tank while an employee steamed the tank. This exposed the employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.252 A03 I
- Issued
- Mar 16, 2021
- Abate by
- Mar 26, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.252(a)(3)(i): Welding, cutting, or other hot work was performed on used drums, barrels, tanks, or other containers that had not been cleaned so thoroughly as to make absolutely certain there were no flammable materials present or any substances such as greases, tars, acids, or other materials which where subjected to heat, might produce flammable or toxic vapors. On or about October 13, 2020, at an oil and gas well pad, a produced water tank was not cleaned so thoroughly as to make absolutely certain there were no flammable materials or any substances, when subjected to heat produce flammable vapors, were present. A contract welder used an oxygen acetylene torch at an exterior surface of the produced water tank and exposed employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Mar 16, 2021
- Abate by
- Mar 26, 2021
- Penalty
- Initial $1,989 · Current $1,193 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met. On or about October 13, 2020, for work at an oil and gas well pad, the employer did not develop and implement at the workplace a written hazard communication program that described how criteria specified at 29 CFR 1910.1200(f), (g), and (h) would be met. At an oil and gas produced water tank, where a pressure washer/steamer and oxygen acetylene torch were used, employees were exposed to hazardous chemicals including, but not limited to, crude oil (flammable) in produced water, Compressed oxygen (oxidizer), Acetylene (flammable), Gasoline (flammable), and Diesel (flammable).
Recent events (2)
- — I (S) $1193.4
- — Z (S) $1989
1910.1200 G01
- Issued
- Mar 16, 2021
- Abate by
- Mar 26, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use. On or about October 13, 2020, establishment, the employer did not have a safety data sheet in the workplace for hazardous chemicals employees used which included, but were not limited to gasoline (flammable) and diesel (flammable) for a hot water pressure washer. This exposed employees to chemical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G08
- Issued
- Mar 16, 2021
- Abate by
- Mar 26, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not ensure that Safety Data Sheets were readily accessible during each work shift to employees when they were in their work area(s). On or about October 13, 2020, for work at oil and gas produced water tanks, the employer did not ensure that a Safety Data Sheet for crude oil (flammable)was readily accessible to employees. This exposed employees to chemical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Mar 16, 2021
- Abate by
- Mar 26, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area. On or about October 13, 2020, for work at an oil and gas well pad, the employer did not provide training on hazardous chemicals in the work area. This exposed employees to hazardous chemicals including, but not limited to the following: Crude oil (flammable) in produced water Compressed oxygen (oxidizer) Acetylene (flammable) Gasoline (flammable) Diesel (flammable)
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 213112)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344979315.