Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CUSTUM EXTERIORS OF GEORGIA, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CUSTUM EXTERIORS OF GEORGIA, LLC in 1900 STANFORD PLACE CT., AUBURN, AL 36831 (NAICS 238130). OSHA activity number 344986872.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Custum Exteriors of Georgia, LLC — free Get an email when a new federal OSHA severe-injury report for Custum Exteriors of Georgia, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1900 STANFORD PLACE CT.
City
AUBURN
State
AL
ZIP
36831
Mailing
225 MCMAKIN DR., SUMMERVILLE, SC 29483
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.502 D01

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 4, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR  1926.502(d)(1):Personal fall arrest system connectors were not drop forged, pressed or formed steel, or made of equivalent materials:  a) On or about October 13, 2020 at 1900 Stanford Place Ct., Auburn, Al: The employer failed to ensure an employee pulling up and installing exterior trim boards had his rope connected to the anchor with a snap hook in that his rope was tied with knot to the D-ring of his harness.
Recent events (1)
  • — Z (S) $4048

1926.502 D15

Serious Gravity 10 2 instances 2 exposed
Issued
Dec 4, 2020
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(15):Anchorages used for attachment of personal fall arrest equipment  was not capable of supporting  at least 5,000 pounds (22.2 kN) per employee attached, or shall be designed, installed, and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person:  a) On or about October 13, 2020 at 1900 Stanford Place Ct., Auburn, Al: The employer failed to ensure an employee pulling up exterior trim boards and installing them was properly anchored in that he wrapped his lanyard around a 2x6  truss board, which is not designed to support a 5,000 pound shock load during a fall, allowing employees to fall 33 feet, 5 5/8 inch to the ground below.  b) On or about October 13, 2020 at 1900 Stanford Place Ct., Auburn, Al: The employer failed to ensure an employee pulling up exterior trim boards and installing them was properly anchored in that he  wrapped his rope around a 2x6 truss board, which is not designed to support a 5,000 pound shock load during a fall, allowing employees to fall 33 feet, 5 5/8 inch to the ground below.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344986872.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.