Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIGUEL DOMINGUEZ

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MIGUEL DOMINGUEZ in RVO425 544 RANDALL ROAD, DELAWARE, OH 43015 (NAICS 238160). OSHA activity number 344986997.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Miguel Dominguez — free Get an email when a new federal OSHA severe-injury report for Miguel Dominguez is published. One employer, no account, unsubscribe in one click.
Establishment
MIGUEL DOMINGUEZ
Site address
RVO425 544 RANDALL ROAD
City
DELAWARE
State
OH
ZIP
43015
Mailing
105 SOUTH RICHARDSON AVENUE, COLUMBUS, OH 43204
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

8 citations on file for this inspection.

1926.404 B01 III C

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 3, 2020
Abate by
Nov 13, 2020
Penalty
Initial $3,181 · Current $3,181
29 CFR 1926.404(b)(1)(iii)(C): Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired.  a) Miguel Dominguez, at a jobsite located at 768 Wharncliff, Lot WEL138, Pickerington, Ohio 43062: On and/or preceding October 20, 2020, the employer did not ensure extension cords were visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Roofers were using a yellow extension cord with missing insulation along its length and a missing ground prong, which exposed the employees to a 123 volt electrical contact hazard.
Recent events (1)
  • — Z (S) $3181

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 3, 2020
Abate by
Nov 13, 2020
Penalty
Initial $3,181 · Current $3,181
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.  a) Miguel Dominguez, at a jobsite located at 768 Wharncliff, Lot WEL138, Pickerington, Ohio 43062: On and/or preceding October 20, 2020, the employer did not ensure employees who used extension cords were protected from electrical contact hazards. Roofers were using a yellow extension cord with the ground prong missing from the male end of a cord, which exposed the employees to a 123 volt electrical contact hazard.
Recent events (1)
  • — Z (S) $3181

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 3, 2020
Abate by
Nov 13, 2020
Penalty
Initial $3,181 · Current $3,181
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  a) Miguel Dominguez, at a jobsite located at Lot RVO425, 544 Randall Road, Delaware, Ohio 43015: On and/or preceding October 20, 2020, the employer did not ensure portable ladders that were used for access to an upper landing surface were extended at least 3 feet (.9 m) above the upper landing surface. Employees were using extension ladders that did not extend at least 3 feet above the edge of the roof, thereby exposed to fall hazards of up to 20 feet.
Recent events (1)
  • — Z (S) $3181

1926.501 B13

Willful Gravity 10 1 instance 2 exposed
Issued
Nov 3, 2020
Abate by
Nov 13, 2020
Penalty
Initial $29,686 · Current $29,686
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure.  a) Miguel Dominguez, at a jobsite located at 768 Wharncliff, Lot WEL138, Pickerington, Ohio 43062: On and/or preceding October 20, 2020, the employer did not ensure employees were adequately protected from falls while engaged in residential construction activities. Employees was installing roofing materials with non-safety rated fall protection equipment, thereby exposed to fall hazards of up to 20 feet.  Miguel Dominguez was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1481682, citation number 2, item number 2 and was affirmed as a final order on September 10, 2020, with respect to a workplace located at 768 Wharncliff, Lot WEL138, Pickerington, Ohio 43062.  Miguel Dominguez was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1926.501(b)(13) which was contained in OSHA inspection number 1418200, citation number 2, item number 1, and was affirmed as a final order on August 23, 2019, with respect to a workplace located at 137 Thrush Circle, Pickerington, Ohio, 43147  Miguel Dominguez was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1926.501(b)(13) which was contained in OSHA inspection number 1261589, citation number 1, item number 1, and was affirmed as a final order on 10/10/2017, with respect to a workplace located at 6400 Brandon Drive, Lewis Center, Ohio.
Recent events (1)
  • — Z (W) $29686

1926.20 B01

Repeat Gravity 10 1 instance 2 exposed
Issued
Nov 3, 2020
Abate by
Nov 23, 2020
Penalty
Initial $22,265 · Current $22,265
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.  a) Miguel Dominguez, at a jobsite located at Lot RVO425, 544 Randall Road, Delaware, Ohio 43015: On and/or preceding October 20, 2020, the employer failed to initiate and maintain a safety and health program such as but not limited to a personal protective equipment program, electrical safety program, fall protection program, and a ladder safety program for employees conducting roofing work.  Miguel Dominguez was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1481682, citation number 2, item number 1 and was affirmed as a final order on September 10, 2020, with respect to a workplace located at 768 Wharncliff, Lot WEL138, Pickerington, Ohio 43062.  Miguel Dominguez was previously cited for a violation of this Occupational Safety and Health standard which was contained in OSHA inspection number 1418200, citation number 1, item number 1, and was affirmed as a final order on August 23, 2019, with respect to a workplace located at 137 Thrush Circle, Pickerington, Ohio, 43147
Recent events (1)
  • — Z (R) $22265

1926.102 A01

Repeat Gravity 5 1 instance 2 exposed
Issued
Nov 3, 2020
Abate by
Nov 13, 2020
Penalty
Initial $6,362 · Current $6,362
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  a) Miguel Dominguez, at a jobsite located at Lot RVO425, 544 Randall Road, Delaware, Ohio 43015: On and/or preceding October 20, 2020, the employer did not ensure employees wore safety glasses while utilizing power tools that presented struck-by hazards to the eyes and face. Roofers were using pneumatic nail guns to secure the shingles. The employees were not utilizing eye protection, which exposed them to struck-by hazards to the eyes.   Miguel Dominguez was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1481682, citation number 1, item number 1 and was affirmed as a final order on September 10, 2020, with respect to a workplace located at 768 Wharncliff, Lot WEL138, Pickerington, Ohio 43062.
Recent events (1)
  • — Z (R) $6362

1926.502 D15

Repeat Gravity 5 1 instance 2 exposed
Issued
Nov 3, 2020
Abate by
Nov 13, 2020
Penalty
Initial $6,361 · Current $6,361
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment shall be independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee attached.  a) Miguel Dominguez, at a jobsite located at Lot RVO425, 544 Randall Road, Delaware, Ohio 43015: On and/or preceding October 20, 2020, the employer did not ensure employees used anchorages capable of supporting 5000 pounds while engaged in residential construction activities. An employee was roofing with a rope tied directly around the top of the trusses at the truss nail plate, thereby exposed to fall hazards of up to 20 feet.  Miguel Dominguez was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1481682, citation number 1, item number 2 and was affirmed as a final order on September 10, 2020, with respect to a workplace located at 768 Wharncliff, Lot WEL138, Pickerington, Ohio 43062.
Recent events (1)
  • — Z (R) $6361

1926.503 A02 II

Repeat Gravity 5 1 instance 2 exposed
Issued
Nov 3, 2020
Abate by
Nov 23, 2020
Penalty
Initial $6,361 · Current $6,361
29 CFR 1926.503(a)(2): The employer shall assure that each employee has been trained, as necessary, by a competent person qualified in the following areas:   29 CFR 1926.503(a)(2)(ii): The correct procedures for erecting, maintaining, disassembling, and inspecting the fall protection systems to be used.  a) Miguel Dominguez, at a jobsite located at Lot RVO425, 544 Randall Road, Delaware, Ohio 43015: On and/or preceding October 20, 2020, the employer did not ensure employees were trained on the correct procedures for erecting a fall protection system while engaged in residential construction activities. Employees were installing shingles without an adequate fall protection system, thereby exposed to fall hazards of up to 20 feet.   Miguel Dominguez was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1481682, citation number 1, item number 3 and was affirmed as a final order on September 10, 2020, with respect to a workplace located at 768 Wharncliff, Lot WEL138, Pickerington, Ohio 43062.
Recent events (1)
  • — Z (R) $6361

View Miguel Dominguez's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344986997.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.