SYRACUSE, NY —
OSHA Inspection: BEAST CONSTRUCTION LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of BEAST CONSTRUCTION LLC in 1801 & 1803 BELLEVUE AVENUE, SYRACUSE, NY 13207 (NAICS 238160). OSHA activity number 344988159.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BEAST CONSTRUCTION LLC
- Site address
- 1801 & 1803 BELLEVUE AVENUE
- City
- SYRACUSE
- State
- NY
- ZIP
- 13207
- Mailing
- 7099 EAST TAFT ROAD, EAST SYRACUSE, NY 13057
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 E01
- Issued
- Feb 25, 2021
- Abate by
- Mar 5, 2021
- Penalty
- Initial $4,096 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a) At the jobsite, on the scaffold, on or about 10/22/20: Workers access and egressed the scaffold platform by climbing over the pick and pick bracket support.
Recent events (3)
- — J (S) $0
- — C (S) $4096
- — Z (S) $4096
1926.451 F06
- Issued
- Feb 25, 2021
- Abate by
- Mar 5, 2021
- Penalty
- Initial $4,096 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. a) At the jobsite, on or about 10/22/20: Employees were working on an aluminum ladder-jack scaffold where that scaffold was within 6 inches of a live power supply line.
Recent events (3)
- — J (S) $0
- — C (S) $4096
- — Z (S) $4096
1926.451 G01
- Issued
- Feb 25, 2021
- Abate by
- Mar 5, 2021
- Penalty
- Initial $4,096 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. a) At the worksite, on the scaffold, on or about 10/22/20: Roofers worked on a ladder jack scaffold, where the pick surface was approximately 19 feet from ground and where no fall protection was provided.
Recent events (3)
- — J (S) $0
- — C (S) $4096
- — Z (S) $4096
1926.501 B13
- Issued
- Feb 25, 2021
- Abate by
- Mar 5, 2021
- Penalty
- Initial $27,306 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) NOTE TO CSHO: USE THIS OPTION ONLY IN CASES WHERE THE INFEASIBILITY/GREATER HAZARD EXCEPTION IS NOT IN ISSUE. a) At the jobsite, on or about 10/22/20: Workers were installing roofing material on a 8:12 pitch roof, with a ground to eave height of 24 feet, without fall protection of any kind.
Recent events (3)
- — J (W) $0
- — C (W) $27306
- — Z (W) $27306
More inspections at Beast Construction LLC
View Beast Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344988159.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.