Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: DE STEEL INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DE STEEL INC. in 5725 OBSERVATION COURT, COLORADO SPRINGS, CO 80916 (NAICS 331210). OSHA activity number 344990510.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DE Steel INC. for free Get an email when a new federal OSHA severe-injury report for DE Steel INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DE STEEL INC.
Site address
5725 OBSERVATION COURT
City
COLORADO SPRINGS
State
CO
ZIP
80916
Mailing
5725 OBSERVATION COURT, COLORADO SPRINGS, CO 80916
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
10
Ownership type
Private (A)

4 citations on file for this inspection.

1910.305 B01 I

Serious Gravity 1 1 instance 4 exposed
Issued
Dec 28, 2020
Abate by
Jan 6, 2021
Penalty
Initial $2,313 · Current $1,388 Reduced
29 CFR  1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:  a) On or about October 22, 2020, and at times prior, workers were exposed to electrical shock hazards while operating a Sunrise ironworker model IW-66K, serial number 13047931, while the foot pedal conductors entering the cabinet were not protected from abrasions.  Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $1387.8
  • · Z (S) $2313

1910.334 A02 II

Serious Gravity 1 2 instances 6 exposed
Issued
Dec 28, 2020
Abate by
Jan 6, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(ii):There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  a) On or about October 22, 2020, and at times prior, workers were exposed to electrical shock hazards while operating a handheld Bosch grinder model GSW 10-45 and another Bosch grinder with cord damage while the tool remained energized and in service.  b)  On or about October 22, 2020, and at times prior, workers were exposed to electrical shock hazards while operating a handheld Bosch grinder connected to a flexible cord set (extension cord) with outer cover damage near the cord end.  Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.29 F04

Other-than-serious 1 instance 4 exposed
Issued
Dec 28, 2020
Penalty
Initial $0 · Current $0
29 CFR  1910.29(f)(4):Openings in a stair rail system exceeded 19 inches at its least dimension:  1) On or about October 22, 2020, and at times prior, workers were exposed to fall hazards at the stair set between the main floor and second level where opening between the stair and top rail was 32 inches without the installation of a mid rail.  Abatement Note: The employer corrected during inspection, the Certification of Corrective Action Worksheet is not required.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.178 L06

Other-than-serious 1 instance 6 exposed
Issued
Dec 28, 2020
Abate by
Jan 6, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(6):The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  a) On or about October 22, 2020, and at times prior, the employer did not prepare a certificate of training to confirm the trained worker was a qualified powered industrial truck operator.  Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344990510.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.