KODIAK, AK ·
OSHA Inspection: TCI CONSTRUCTION COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TCI CONSTRUCTION COMPANY in U.S. ARMY CORPS OF ENGINEERS PROJECT, BUILDING N23 BUSKIN WATERLINE REPLACEMENT, KODIAK, AK 99615 (NAICS 237110). OSHA activity number 344993464.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TCI CONSTRUCTION COMPANY
- Site address
- U.S. ARMY CORPS OF ENGINEERS PROJECT, BUILDING N23 BUSKIN WATERLINE REPLACEMENT
- City
- KODIAK
- State
- AK
- ZIP
- 99615
- Mailing
- 3680 LATHROP ST., FAIRBANKS, AK 99701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 20
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.652 A01
- Issued
- Jan 29, 2021
- Abate by
- Feb 26, 2021
- Penalty
- Initial $4,915 · Current $3,500 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). a) Building N23 - On or about October 20, 2020, employees installed water piping into a ten (10) feet deep trench and were exposed to cave-in hazards while working outside the trench box and in areas of the trench that did not contain an adequate protective system.
Recent events (2)
- · I (S) $3500
- · Z (S) $4915
1926.652 G01 III
- Issued
- Jan 29, 2021
- Abate by
- Feb 26, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(g)(1)(iii):Employees were not protected from the hazard of cave-ins when entering or exiting the area protected by shields: a) Building N23 - On or about October 20, 2020, employees installed water piping into a ten (10) feet deep trench, but were not protected from the hazards of cave-ins when entering and exiting the trench because the ladder was positioned outside the trench box.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.652 C02 I
- Issued
- Jan 29, 2021
- Abate by
- Feb 10, 2021
- Penalty
- Initial $2,809 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data were not in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer: a) Building N23 - On or about October 20, 2020, employees installed water piping in a ten (10) feet deep trench and were exposed to overhead hazards when working in a trench box not positioned at least 18 inches above the beginning of the slope.