Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CLARK, SMOOT, CONSIGLI, A JOINT VENTURE

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of CLARK, SMOOT, CONSIGLI, A JOINT VENTURE in 600 INDEPENDENCE AVENUE, SW, WASHINGTON, DC 20560 (NAICS 236220). OSHA activity number 344995147.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clark, Smoot, Consigli, a Joint Venture — free Get an email when a new federal OSHA severe-injury report for Clark, Smoot, Consigli, a Joint Venture is published. One employer, no account, unsubscribe in one click.
Site address
600 INDEPENDENCE AVENUE, SW
City
WASHINGTON
State
DC
ZIP
20560
Mailing
7500 OLD GEORGETOWN ROAD, BETHESDA, MD 20814
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
48
Ownership type
A

5 citations on file for this inspection.

1926.20 B02

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Mar 24, 2021
Penalty
Initial $13,653 · Current $0 Reduced
29 CFR 1926.20(b)(2):The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):  a) Gallery 102 - While on the second floor, employees entered and were removing material from an Electro-Elsa material hoist, model number M20S, serial number 880711, where the loading dock door was not secure in that it was missing a door slide latch, and had a broken or missing door guide, exposing employees to a fall hazard of 28 feet and 11 inches, on or about 09/28/2020.  NO ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $13653

1926.200 B01

Other-than-serious Gravity 10 1 instance 3 exposed
Issued
Mar 24, 2021
Penalty
Initial $0 · Current $13,653
29 CFR 1926.200(b)(1): A danger sign  was not used where an immediate  hazard exists:  a) Gallery 102 - While on the second floor, employees entered and were removing material from an Electro-Elsa material hoist, model number M20S, serial number 880711, where the loading dock door was not secure in that it was missing a door slide latch, and had a broken or missing door guide, exposing employees to a fall hazard of 28 feet and 11 inches, and a danger sign was not posted on or about 09/28/2020.   ABATEMENT DOCUMENTATION NOT REQUIRED
Recent events (2)
  • — I (O) $13653
  • — Z (S) $0

1926.200 H01

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Mar 24, 2021
Penalty
Initial $0 · Current $0
29 CFR 1926.200(h)(1):  Accident prevention tags were not used a temporary means of warning employees of an existing hazard, such as defective tools, equipment, etc.   a) Gallery 102 - While on the second floor, employees entered and were removing material from an Electro-Elsa material hoist, model number M20S, serial number 880711, that was not tagged as defective or out of service, where the loading dock door was not secure in that it was missing a door slide latch, and had a broken or missing door guide, exposing employees to a fall hazard of 28 feet and 11 inches, on or about 09/28/2020.  Or In the Alternative:  29 CFR 1926.20(b)(3): Machinery, tool(s), material(s), or equipment which was not in compliance with the applicable requirement(s) of 29 CFR 1926 was not prohibited, and/or was not either identified as unsafe by tagging, or locking the controls to render them inoperable, or physically removed from its place of operation.   a) Gallery 102 - While on the second floor, employees entered and were removing material from an Electro-Elsa material hoist, model number M20S, serial number 880711, that was not tagged as defective or out of service, where the loading dock door was not secure in that it was missing a door slide latch, and had a broken or missing door guide, exposing employees to a fall hazard of 28 feet and 11 inches, on or about 09/28/2020.  ABATEMENT DOCUMENTATION NOT REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.552 B01 I

Deleted Other-than-serious 1 instance 3 exposed
Issued
Mar 24, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.552(b)(1)(i):Operating rules were not established and posted at the operator's station of the material hoist:  a) Gallery 102 - Operating rules were not posted at the operator's station of an Electro-Elsa material hoist, model number M20S, serial number 880711, used by employees to move drywall and insulation on or about September 28, 2020.  ABATEMENT DOCUMENTATION NOT REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.552 B04

Deleted Other-than-serious 1 instance 1 exposed
Issued
Mar 24, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.552(b)(4):The operator's station of a hoisting machine was not provided with overhead protection equivalent to tight planking at least 2 inches thick, with supports of equal strength:  a) Gallery 102 - The operator's station for the Electro-Elsa material hoist, model #M20S, serial number 880711, used by employees to move drywall and insulation, had a three quarter inch piece of plywood for overhead protection, on or about 09/28/2020.  ABATEMENT DOCUMENTATION NOT REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344995147.